Panasonic cu-4ks24nbu User Manual

Page of 114
Outdoor Unit  :  CU-4KS31NBU
Indoor Unit 
:  CS-MKS9NKU 
×
 4
Power Supply  :  230V Single Phase 60Hz
 RATING CAPACITY:    30,600 BTU/h
      AIR FLOW RATE:
1,036 CFM
INDOOR
OUTDOOR
 ENT. TEMP. 
o
F (
o
C)
    AMBIENT TEMP. 
o
F (
o
C)
WB
DB
0
5
15
25
35
45
55
(-17.8)
(-15.0)
(-9.4)
(-3.9)
(1.7)
(7.2)
(12.8)
TC
30,870
30,760
30,800
31,010
30,890
72 (22.2)
SHC
24,260
30,760
24,260
24,260
24,260
59
76 (24.4)
SHC
27,890
30,760
27,890
27,890
27,890
(15.0)
80 (26.7)
SHC
30,870
30,760
30,800
31,010
30,890
84 (28.9)
SHC
30,870
30,760
30,800
31,010
30,890
88 (31.1)
SHC
30,870
30,760
30,800
31,010
30,890
TC
31,140
31,130
31,320
31,720
31,730
72 (22.2)
SHC
19,640
31,130
19,840
19,840
19,840
63
76 (24.4)
SHC
23,260
31,130
23,260
23,460
23,460
(17.2)
80 (26.7)
SHC
26,880
31,130
27,080
27,280
27,280
84 (28.9)
SHC
30,500
31,130
30,700
30,700
30,700
88 (31.1)
SHC
31,140
31,130
31,320
31,720
31,730
TC
31,150
31,270
31,660
32,300
32,450
72 (22.2)
SHC
15,010
31,270
15,210
15,410
15,610
67
76 (24.4)
SHC
18,630
31,270
18,830
19,030
19,030
(19.4)
80 (26.7)
SHC
22,250
31,270
22,450
22,860
22,860
84 (28.9)
SHC
25,870
31,270
26,080
26,280
26,480
88 (31.1)
SHC
29,490
31,270
29,700
29,900
29,900
TC
30,850
31,120
31,750
32,680
33,020
72 (22.2)
SHC
10,180
31,120
10,380
10,790
10,790
71
76 (24.4)
SHC
13,600
31,120
14,010
14,410
14,410
(21.7)
80 (26.7)
SHC
17,430
31,120
17,630
18,030
18,230
84 (28.9)
SHC
21,050
31,120
21,250
21,650
21,650
88 (31.1)
SHC
24,470
31,120
24,870
25,270
25,270
TC
30,230
30,670
31,570
32,820
33,340
75
76 (24.4)
SHC
8,980
30,670
9,380
9,780
9,980
(23.9)
80 (26.7)
SHC
12,600
30,670
13,200
13,600
13,600
84 (28.9)
SHC
16,220
30,670
16,620
17,020
17,220
88 (31.1)
SHC
19,840
30,670
20,240
20,640
20,840
NOTE
< Cooling Capacity (Low Ambient) >
TC : Total Cooling Capacity (BTU/h)   SHC : Sensible Heat Capacity (BTU/h)
1.
2. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account. 
For this reason, the value may vary from the actual cooling characteristics.
60