Panasonic cu-4ks24nbu User Manual

Page of 114
Outdoor Unit  :  CU-4KS24NBU
Indoor Unit 
:  CS-MKS9NKU 
×
 3
Power Supply  :  230V Single Phase 60Hz
NOTE
 RATING CAPACITY:    25,400 BTU/h
      AIR FLOW RATE:
777 CFM
INDOOR
OUTDOOR
 ENT. TEMP. 
o
F (
o
C)
    AMBIENT TEMP. 
o
F (
o
C)
WB
DB
15
25
35
45
55
(-9.4)
(-3.9)
(1.7)
(7.2)
(12.8)
TC
25,470
25,420
25,470
25,670
25,610
72 (22.2)
SHC
19,250
25,420
19,250
19,410
19,410
59
76 (24.4)
SHC
21,970
25,420
21,970
22,120
22,120
(15.0)
80 (26.7)
SHC
24,840
25,420
24,840
24,840
24,840
84 (28.9)
SHC
25,470
25,420
25,470
25,670
25,610
88 (31.1)
SHC
25,470
25,420
25,470
25,670
25,610
TC
25,540
25,590
25,780
26,160
26,210
72 (22.2)
SHC
15,780
25,590
15,780
15,940
16,090
63
76 (24.4)
SHC
18,350
25,590
18,500
18,650
18,650
(17.2)
80 (26.7)
SHC
21,220
25,590
21,370
21,520
21,520
84 (28.9)
SHC
23,930
25,590
23,930
24,080
24,230
88 (31.1)
SHC
25,540
25,590
25,780
26,160
26,210
TC
25,380
25,550
25,930
26,510
26,700
72 (22.2)
SHC
12,010
25,550
12,310
12,470
12,620
67
76 (24.4)
SHC
14,730
25,550
15,030
15,180
15,330
(19.4)
80 (26.7)
SHC
17,600
25,550
17,750
18,050
18,050
84 (28.9)
SHC
20,160
25,550
20,460
20,610
20,760
88 (31.1)
SHC
22,880
25,550
23,180
23,330
23,480
TC
24,930
25,240
25,840
26,690
27,040
72 (22.2)
SHC
8,240
25,240
8,540
8,840
9,000
71
76 (24.4)
SHC
10,960
25,240
11,260
11,560
11,710
(21.7)
80 (26.7)
SHC
13,670
25,240
13,970
14,280
14,430
84 (28.9)
SHC
16,390
25,240
16,690
16,990
17,140
88 (31.1)
SHC
19,100
25,240
19,410
19,710
19,860
TC
24,210
24,680
25,530
26,670
27,190
75
76 (24.4)
SHC
7,190
24,680
7,640
7,940
8,240
(23.9)
80 (26.7)
SHC
10,050
24,680
10,500
10,810
10,960
84 (28.9)
SHC
12,620
24,680
13,070
13,520
13,670
88 (31.1)
SHC
15,330
24,680
15,780
16,090
16,390
< Cooling Capacity (Low Ambient) >
TC : Total Cooling Capacity (BTU/h)   SHC : Sensible Heat Capacity (BTU/h)
1.
2. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account. 
For this reason, the value may vary from the actual cooling characteristics.