SYSTEM CONNECTIONS
Connection to the WJ-MP204 Data Multiplex Units (Panasonic Security Data
Mode)
The supplied 6-conductor cable permits easy connection by simply plugging it into the data port (DATA) of the WJ-MP204
Data Multiplex Unit(s) and the other end into one end of the same port (DATA) of the System Controller.
If you are using locally purchased cables, make sure that they are 2-wire twisted pair shielded cables of data grade suited to
the RS-485. Low-grade cables will cause instability of system operation.
DC 9V IN
Connection with the AC Adapter
Insert the DC plug of the supplied AC adapter into the DC
9V input jack (DC 9V IN) on the System Controller. Then,
plug the AC adapter into an AC outlet.
SD
RD
IN
IN
CAMERA
RS485
A
B
A
B
G
VS/VD
SPOT
DATA
A L A R M   /   R E M OT E
MODE
SIGNAL GND
4
3
2
1
OUT
OUT
IN
OUT
4
3
2
1
T
R
IN
IN
CAMERA
RS485
A
B
A
B
G
VS/VD
SPOT
DATA
A L A R M   /   R E M OT E
MODE
SIGNAL GND
4
3
2
1
OUT
OUT
IN
OUT
4
3
2
1
Camera No. 1
Camera No. 2
Camera No. 3
Camera No. 4
Camera No. 5
Camera No. 6
Camera No. 7
Camera No. 8
VS/VD INPUT
SPOT OUT
SPOT SW OUT
SPOT SW IN
SPOT IN
Unit Address 1
Unit Address 2
WJ-MP204
WJ-MP204
Termination ON
Supplied 6-Conduntor Modular Cable
Up to four WV-CU360s 
can be used in a system.
Monitor
MODE
VS/VD OUTPUT 
4-Line
Panasonic Security 
Data mode
Termination OFF
Panasonic Security 
Data mode
4-Line
MODE
VD OUT
DC 9V IN
DATA
MODE
CONTROLLER No.
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
Keep the OFF position
Keep the OFF position
Termination ON
Set the position to OFF 
(for operator mode) 
Controller No.1
Refer to DIP switch setting (See page 9)
CONTROLLER No.
Video Signal
RS-485 Signal