3. Enter a camera number (01 to 199) for cleaning first
using Numeric buttons. The initial factory setting is [no-
01].
4. Press the CAM/SET button. Camera Cleaning starts.
5. The LED display shows a two-digit animations for clean-
ing on the left and a two-digit or a three-digit camera
numbers (01-199) on the right.
6. The last camera number appears when camera clean-
ing is over.
7. To return to the previous display, press the MON/ ESC
button.
Notes:
• To cancel the camera cleaning, press the MON/
ESC button.
• Camera surveillance is disabled while camera
cleaning continues.
• All cameras are automatically cleaned in order.
• Camera cleaning setting is valid only in cases
where a combination camera is connected to the
system.
Unit Connection Test Setting (12)
Check that the power of the cameras and the other units
are switched on.
1. Select [UtESt] by moving the joystick up or down.
2. Press the CAM/SET button. [01-on] or [01-oF] appears.
3. Press the CAM/SET button. The unit connection test
starts (01-99).
4. The LED display shows a two-digit unit addresses on
the left and a two-digit animations for testing on the
right.
5. The last unit address appears when the unit test is over.
6. Press the CAM/SET button.
7. If you enter the unit address using numeric buttons after
finished it, you can confirm whether the unit is connect-
ed or not. Enter a 2-digit unit address to confirm the
connection. When [**-on] appears, the unit is connect-
ed. When [**-oF] (OFF) appears, the unit is not con-
nected.
8. To return to the previous display, press the MON/ESC
button.
Notes:
• [**] displays the selected unit address (01-99).
• To cancel the unit connection test, press the MON/
ESC button.
• Camera surveillance is disabled while the unit con-
nection test continues.