INSTALLATIONS
DIP Switch Setting
Set the DIP switches located on the rear of the system con-
troller.
The initial factory settings are shown below.
Caution:
Keep the power off before changing any DIP
switch setting.
MODE
1
2
3
4
5
6
7
8
OFF
ON
• DIP Switches 1, 2, 3, 4, 7, 8
These switches are reserved for mode setting.
Normally, keep them in the OFF position.
• DIP Switch 5
Used for termination setting.
Check that this switch is in the ON position.
Note:
If two or more system controllers are used in a
system via RS-485, set SW5 on only one point at the
end position of the system controller to the ON posi-
tion.
Controller Number Setting
Controller No. Switch of WV-CU360
Controller No.
0
Reserved
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
Reserved
Notes:
• Set the controller No. switch to No. 1 to use only one
system controller.
• Do not set the switch to No. 0 or 9 because these num-
bers are reserved.
• If a system has two or more system controllers, set dif-
ferent controller numbers to them. However, set the
controller No. switch in one of them to No.1.
• Keep the power off while setting controller numbers.
The set numbers are invalid if power is on.
CONTROLLER No.
0
9
8
7
6
5
4
3
2
1
The installation should be made by qualified service personnel or system installers only according to the following
instructions.
Turn the CONTROLLER No. (address
setting) switch till the arrow points the
desired number.
• DIP Switch 6
Used to select a mode for setup or normal operation.
Set DIP Switch 6 to OFF after completing the setup.
SW6 position for administrator setup mode: ON
SW6 position for operator mode: OFF
MODE
1
2
3
4
5
6
7
8
OFF
ON
MODE
1
2
3
4
5
6
7
8
OFF
ON
Operator mode
Administrator mode
System Unit
WV-CU360
Termination 
OFF
Controller No. 3
Termination 
OFF
Controller No. 2
Termination 
ON
Controller No. 1
Termination 
ON
WV-CU360
WV-CU360