SETUP MENU
Displaying the Setup Menu
1. Check that DIP Switch 6 is set to ON (Administrator
mode).
2. Connect the DC plug to the DC 9V IN jack and the AC
adapter to an AC outlet. The power of WV-CU360 is
supplied.
3. Check that the cameras and the other units are con-
nected correctly and securely.
4. Switch the cameras and other system units on.
5. [SEtUP] appears.
6. Press the CAM/SET button. [˚ ˚ ˚ ˚ ˚] appears blinking.
7. Enter the Administrator Password. The default is
[12345]. Then press the CAM/SET button. [SPEEd]
appears.
8. You can proceed to another setting menu by moving
the joystick up or down.
9. Press the CAM/SET button.
The existing settings appear.
10. To change a parameter, press the CAM/SET button
after confirming the existing settings.
For details on changing the settings, see the corre-
sponding parts of this page and the next.
11. Select a parameter by entering a number using numeric
buttons, by moving the joystick to the left or right, or by
pressing STILL/– button or EL ZOOM/+ button.
12. Press the CAM/SET button to set the entry. The set
value appears on the LED display. The set data is
saved in the memory of the WV-CU360. The setting is
completed. To return to the previous menu, press MON/
ESC button. To set another parameter, repeat proce-
dures 8 to 12.
13. After disconnect the AC adapter from the AC outlet, set
Dip Switch 6 back to OFF (Operator mode).
Notes:
• If the administrator password fails in obtaining autho-
rization, [Error] appears blinking for 2 seconds on the
LED display, followed by [SEtUP].
• After DIP Switch 6 is set to OFF (Operator mode), the
system is ready for setting up the cameras and the
other units . For details, see pages 28, 29 and 30.
• The Group Addresses of the WV-CU360 and System
Units on the Setup menu should be left as they are.
• All the settings must be compatible with the system
units connected.
• To return to the factory default settings, reset all (See
page 27).
Baud Rate Setting (01)
1. Select [SPEEd] by moving the joystick up or down.
2. Press the CAM/SET button. [SP-96] appears.
3. Press the CAM/SET button.
4. Enter 3 (9 600), 4 (19 200), 1 (2 400), or 2 (4 800) using
numeric button. Or, select the desired baud rate 96
(9 600), 192 (19 200), 24 (2 400), or 48 (4 800) (bps) by
moving the joystick to the left or right.
The initial factory setting is 9600 bps.
5. Press the CAM/SET button.
6. To return to [SPEEd], press MON/ESC button.
Notes:
• The desired parameter is also selected by pressing
STILL/– button or EL-ZOOM/+ button.
• If the baud rate is set to 2 400 bps, instability of
data response may occur when the alarm is reset,
for example.
The Setup menu is used to set communication parameters and a user password etc. for system units compatible with
Panasonic Security Data mode.
Setup Menu
BAUD RATE
PARITY CHECK
WAIT TIME
CONTROLLER UNIT- GROUP ADDRESS
SYSTEM UNIT- GROUP ADDRESS
UNIT A NUMBER
UNIT B NUMBER
USER PASSWORD
ADMINISTRATOR (SUPER USER) PASSWORD
USER AUTHORIZATION (CERTIFICATION)
CAMERA CLEANING
UNIT CONNECTION TEST