2.5 RCI Setup for Replacement of an RCI I/O Unit
2.5
RCI Setup for Replacement of an RCI I/O Unit
2.5.1
RCI setup flow
RCI setup for replacement of an RCI I/O unit contains the following steps:
1
2
3
Note:
Perform this RCI setup work for each RCI I/O unit to be replaced.
2.5.2
Confirming an RCI address
Confirm the RCI address or location of the RCI I/O unit to be replaced.
• To confirm an RCI address:
1
Push the service pin of the RCI I/O unit to be replaced.
2
Execute the setrci (8) command to display the address of the RCI I/O unit
whose service pin is pushed.
whose service pin is pushed.
If the RCI I/O unit to be replaced has failed and cannot make a transmission, its RCI
address cannot be confirmed by the above operation. Perform the following operation
to confirm the RCI address.
address cannot be confirmed by the above operation. Perform the following operation
to confirm the RCI address.
XSCF> setrci -c idpin
RCI:XXXX VER:XX DATE:XXXX XX/XX XX:XX;XX
The command completed successfully.
RCI:XXXX VER:XX DATE:XXXX XX/XX XX:XX;XX
The command completed successfully.