2.5  RCI Setup for Replacement of an RCI I/O Unit
2.5
RCI Setup for Replacement of an RCI I/O Unit
2.5.1
RCI setup flow
RCI setup for replacement of an RCI I/O unit contains the following steps: 
1
2
3
Note:
Perform this RCI setup work for each RCI I/O unit to be replaced.
2.5.2
Confirming an RCI address
Confirm the RCI address or location of the RCI I/O unit to be replaced.
• To confirm an RCI address:
1
Push the service pin of the RCI I/O unit to be replaced.
2
Execute the setrci (8) command to display the address of the RCI I/O unit 
whose service pin is pushed.
If the RCI I/O unit to be replaced has failed and cannot make a transmission, its RCI 
address cannot be confirmed by the above operation.  Perform the following operation 
to confirm the RCI address.
XSCF> setrci -c idpin
RCI:XXXX VER:XX DATE:XXXX XX/XX XX:XX;XX
The command completed successfully.