Binary values (1/0) are displayed in an 8-digit row identified as 1 through 8 from right
to left.
X
X
X X
X
X
X
X
8
7
6
5
4
3
2
1
PARA-
METER FUNCTION
PAR00
Feedback configuration, different per axis. Binary type.
This parameter sets the specific characteristics of the feedback
device (rotary or linear encoder) used to read the axis position.
Digit
8
Direction of the distance-coded Io (0 = Increasing, 1 = Decreasing)
Fagor offers two types of linear encoders depending on the type of
reference marks they use (Io): the standard one with several reference
marks every 50 mm and the one with distance-coded reference marks
(models with "O", e.g.: MOVX, FOP, etc.).
When using a rotary encoder or a standard Fagor linear encoder
(without "O") for this axis, this bit must be set to "0".
When using an "M" or "F" series Fagor linear encoders with
distance-coded reference marks
 (e.g.: MOVX,  FOP) for this
axis, this bit must be set to "0".
When using a "C" type linear encoder with distance-coded reference
marks
, (e.g.: COX, COVP) for this axis, this bit must be set to "1".
7
Pitch of the distance-coded Io (0 = 20 mm, 1 = 100 mm)
This bit is ignored if bit 6 has been set to "0".
When using Fagor M or C series linear encoders, this bit must be "0".
When using Fagor F series linear encoders, this bit must be "1".
6
Type of linear scale's Io (0 = Fix, 1 = Coded)
Fagor offers two types of linear encoders depending on the type of
reference marks they use (Io): the standard one with several reference
marks every 50 mm and the one with distance-coded reference marks
(models with "O" e.g.:  MOVC, COS, etc.).
When using a rotary encoder or a standard Fagor linear encoder, this
bit must be set to "0".