4.
OPERATION WITH THE RS-232-C SERIAL LINE
4.1.
SAVING AND RESTORING DATA
With this NC, it is possible to save data into a PC or peripheral device and later
restore it by using the RS-232-C serial communications line.
This data is sent out in the following format:
Baudrate as set by PAR90, 8 data bits, 1 stop bit and no parity.
To access this mode:
- Press 
F
- Select the "Com" option (communications) of the LCD display by means of
the 
 
  and press 
.
- Select: <Send> and press 
  to send the data out to a PC or peripheral
device or select  <Receive>  and press 
  to receive data from a PC or
peripheral device.
- Select the type of data to transmit Parameters, Program, Materials by means
of the 
 
  keys and press 
 .
4.2
PARAMETER TRANSMITTING FORMAT
The format of the transmitted parameters are:
For value parameters:
P?? 123.123
For binary parameters:
P?? 10101010
For option parameters:
P?? 0
For axis parameters:
P?? X 123.123  Y 123.123