Nilfisk attix 751-2m User Manual

Page of 18
12
english
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
1) 
Option depending on model
7.2.5  Replacing filter element 
(ATTIX 360-2M/550-2M/
751-2M)
1. Open the retaining clamps 
and remove the upper section 
of the cleaner from the dirt 
tank. Lay the upper section of 
the cleaner down with the filter 
element facing upwards.
2.  Turn the filter holder anticlock-
wise (1) and remove it (2).
3.  Place the protective filter bag
1)
 
over the filter element (3).
4.  Carefully remove the filter ele-
ment and close the protective 
filter bag with a knot.
5.  Clean the filter seal (4). Check 
it for damage and replace it if 
necessary.
6.  Check the antistatic clamp (5) 
for damage and have it re-
placed by Nilfisk-Alto Service 
if necessary.
7.  Fit a new filter element.
8.  Check that the float (6) works 
properly. When the filter holder 
is turned, the float inside must 
move about easily.
9.  Fit the filter holder and turn it 
clockwise to secure it firmly.
10. Dispose of the used filter ele-
ment in accordance with legal 
regulations.
Never use the vacuum cleaner 
without a filter.
During the following work, ensure 
that dust is not unnecessarily 
spread around. Wear a P2 breath-
ing mask.
1) 
Accessory. Order No. shown in section 9.5.
3
6
1
2
1
2
5
4
7.2.6  Replacing filter element 
(ATTIX 560-2MXC/
761-2MXC)
During the following work, ensure 
that dust is not unnecessarily 
spread around. Wear a P2 breath-
ing mask.
1. Open the retaining clamps 
and remove the upper sec-
tion of the cleaner from 
the dirt tank. Lay the upper 
section of the cleaner down 
with the filter element facing 
upwards. Do not place the 
upper section of the cleaner 
on the guard (1) and do not 
damage the filter element.
2.  Open the bar handle (2) and 
remove it.
3.  Remove the filter holder (3).
4. Place the protective filter 
bag 
1) 
over the filter element.
5. Carefully remove the filter 
element and close the pro-
tective filter bag with a knot.
6. Clean the filter seal (4). 
Check it for damage and 
replace it if necessary.
4
1
3
2