Nilfisk attix 751-2m User Manual

Page of 18
13
english
ATTIX 360-2M
ATTIX 550-2M / ATTIX 560-2MXC
ATTIX 751-2M / ATTIX 761-2MXC
1) 
Option depending on model
7. Check the antistatic clamp 
(5) for damage and have it 
replaced by Nilfisk-Alto Serv-
ice if necessary.
8. Check that the control flap 
(6) for filter cleaning works 
properly. The control flap 
should move back and for-
wards easily.
9.  Clean the level hose (7).
10. Fit a new filter element.
11. 
Fit the filter holder. Ensure 
that it is in the correct posi-
tion.
12. Fit bar and close bar handle.
13. 
Dispose of the used filter 
element in accordance with 
legal regulations.
Never use the vacuum cleaner 
without a filter.
1) 
Accessory. Order No. shown in section 9.5.
5
7
6
8 Troubleshooting
Fault
Cause
Remedy
‡ Motor does not start
> Fuse of the mains socket has 
blown.
Connect mains fuse.
> Overload protection switch 
has tripped.
Switch off the vacuum cleaner 
and allow it to cool for approx. 
5 minutes. If the cleaner can-
not be started again, contact 
the Nilfisk-Alto service depart-
ment.
> Self-acting carbon brush is 
worn.
Have carbon brushes changed 
by Nilfisk-Alto Service.
‡ Motor does not run in auto-
matic mode
> Power tool is defective or not 
connected properly.
Check that the power tool 
works or that the plug is in-
serted correctly.
> The power rating of the elec-
trical tool is too low.
Note that minimum power rat-
ing is P>40W
‡ The acoustic warning 
sounds. (Reduced suction 
power)
> Suction power selected with 
suction power control is too 
low.
Set suction power in accord-
ance with section 4.2.3. „Set-
ting suction power“.
> Hose diameter and switch 
position do not correspond.
Set correct switch position for 
hose diameter.
> Clogged suction hose/nozzle.
Clean suction hose/nozzle
> Filter bag is full.
See section 7.2.2 „Replacing 
filter bag“.