Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
4-27
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Chapter 4      Removal and Replacement Procedures
  Removing and Installing the DC-Input Power Supplies
Step 7
Grasp both power supply handles, as shown in 
, and slide the power supply completely out 
of the chassis.
Figure 4-19 Handling a DC-Input Power Supply 
Step 8
If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco part number 
700-03104-01) over the opening, and secure it with the captive installation screws.
Installing a 2700 W DC-Input Power Supply
Warning
Before performing any of the following procedures, ensure that power is removed from the DC 
circuits. To ensure that all power is removed, locate the circuit breakers or fuses on the DC power 
lines that service the DC circuits. Turn OFF the DC power line circuit breakers and remove the DC 
power line fuses. 
Statement 322 
To install a DC-input power supply, follow these steps:
Step 1
Ensure that the system (earth) ground connection has been made. For ground connection installation 
instructions, see the 
Step 2
Remove the plastic bag attached to the front panel and put aside. This bag contains two plastic terminal 
block barriers, two cable ties, and two cable holder covers.
Step 3
Verify that power is off to the DC circuit on the power supply that you are installing. As an added 
precaution, place the appropriate safety flag and lockout devices at the source power circuit breaker, or 
place a piece of adhesive tape over the circuit breaker handle to prevent accidental power restoration 
while you are working on the circuit.
Grasp both power supply handles, as shown in 
Slide the power supply into the power supply 
bay. Make sure that the power supply is fully seated in the bay.
126567
PWR-2700-DC/4
ALL FAST
ENERS M
UST BE F
ULLY ENG
AGED
PRIOR TO
 OPERATIN
G THE PO
WER SUP
PLY
INPUT1
OK
48V-60V
=40A
INPUT2
OK
48V-60V
=40A
FAN
OK
OUTPUT
FAIL
-VE-1
-VE-1
-VE-2
-VE-2
ALL FAST
ENERS M
UST BE F
ULLY ENG
AGED
PRIOR TO
 OPERATIN
G THE PO
WER SUP
PLY
INPUT1
OK
48V-60V
=40A
INPUT2
OK
48V-60V
=40A
FAN
OK
OUTPUT
FAIL
PWR-2700-DC/4