  Removing and Installing the DC-Input Power Supplies
Step 7
Loosen the captive installation screw on the power supply. (See 
Caution
Use both hands to install and remove power supplies. The 4000 W DC-input power supply weighs 
32 pounds (14.5 kg).
Step 8
Grasp the power supply handle with one hand, and slide the power supply part of the way out of the 
chassis. Place your other hand underneath the power supply, as shown in 
, and slide the 
power supply completely out of the chassis.
Figure 4-26 Handling a 4000 W DC-Input Power Supply 
Step 9
If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco part number 
700-03104-01) over the opening, and secure it with the captive installation screws.