Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
D-1
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
A P P E N D I X
D
Chassis and Module Power and Heat Values
This appendix provides the power and heat numbers for the Catalyst 6500 series chassis and modules.
Chassis and fan trays—
IP phones—
Supervisor Engine—
Modules—
Unless otherwise noted, the information in the following tables is measured under fully-loaded 
conditions (transceivers installed). Typical numbers are approximately 30 percent below the numbers 
listed in these tables.
Note
Module power is the output from the power supply (internal to the system). The AC-input power is the 
input from the outlet to the power supply. The percentage difference between the two values is the 
efficiency of the power supply.
Table D-1
Power Requirements and Heat Dissipation—Chassis and Fan Trays
Model Number/
Module Type
Module 
Current (A)
Module 
Power 
(Watts)
AC
DC
AC-Input
Power 
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power 
(Watts)
Heat Diss.
(BTU/HR)
Catalyst 6503 chassis
FAN-MOD-3 fan tray
0.80
34.00
43.00
145.00
46.00
156.00
FAN-MOD-3HS fan tray
2.98
125.16
156.45
534.28
168.23
574.49
Catalyst 6503-E chassis
WS-C6503-E-FAN fan tray
1.37
57.54
71.93
245.62
77.34
264.11
Catalyst 6504-E chassis
FAN-MOD-4HS fan tray
1.43
60.06
75.08
256.38
80.73
275.68
Catalyst 6506 chassis 
WS-C6K-6SLOT-FAN fan tray
0.71
30.00
37.48
128.00
40.00
136.88
WS-C6K-6SLOT-FAN2 fan tray
2.00
84.00
105.00
359.00
113.00
386.00