Rommelsbacher CT 2215/IN User Manual

Page of 28
26
•  Make sure no water or steam may infi ltrate the appliance from below either. 
•  Never use abrasives, steel wool or sharp, scratchy objects.
•  If there is any dirt visible in the area of the ventilation slots, it can be removed from the out-
side by means of a vacuum cleaner.
The electronic control features several internal monitoring functions. If an error occurs, the 
power supply will be quit and an error code will appear on the display. 
Error code table:
E0 
Overcurrent: The power consumption of the appliance exceeded the maximum allowable 
 
15 Amps. 
 
Self-help: Make sure the appliance is connected to the mains voltage indicated on the 
 
rating label.
E1 
Electronic control of low voltage: An error has occurred in an electronic circuit of the 
 
appliance due to excessively low voltage (< 160 V~).  
 
Self-help: Make sure the appliance is connected to the mains voltage indicated on the 
 
rating label.
E2 
Electronic control of excess voltage: An error has occurred in an electronic circuit of the 
 
appliance due to excessively high voltage (> 270 V~).  
 
Self-help: Make sure the appliance is connected to the mains voltage indicated on the 
 
rating label.
E3 
Control unit: An error has occurred on the IGBT control unit of the appliance. 
 
Self-help: Not possible – the appliance must certainly be forwarded to the customer 
 
service.
E4 
Short circuit: A short circuit was caused in an electronic circuit of the appliance. 
 
Self-help: Not possible – the appliance must certainly be forwarded to the customer 
 
service.
E5 
Overheating protection (“power level” mode): The temperature on the cooktop exceeds 
 
the maximum allowable value of 200 °C during “power level” operating mode (e. g. due 
 
to hot oil or fat, or an empty pot or any other metal object while appliance is switched on). 
 
Self-help: Eliminate the cause of overheating. Once the cooktop has cooled, the appli-
 
ance can be put into operation again. Afterwards use the “temperature level” mode for 
 
constantly higher temperatures over 200 °C.
E6 
Temperature sensor: The temperature sensor underneath the glass ceramic plate is 
 
defective.
 
Self-help: Not possible – the appliance must certainly be forwarded to the customer 
 
service.
Error codes