E7 
Overheating protection (“temperature level” mode): The temperature on the cooktop 
 
exceeds the maximum allowable value of 240 °C during “temperature level” mode (e. g. 
 
due to an empty pot or any other metal object while appliance is switched on). 
 
Self-help: Eliminate the cause of overheating. Once the cooktop has cooled, the appli-
 
ance can be put into operation again.
E8 
Temperature sensor: The temperature sensor underneath the glass ceramic plate provi-
 
des an undefi ned signal. 
 
Self-help: Make sure no metal objects or other foreign objects were placed on the cooktop. 
E11 
Inside temperature: The interior of the appliance has become too warm (e. g. by hin-
 
dered air supply, blocked or defective fan or excessive ambient temperature). 
 
Self-help: Clean the air vents or remove any foreign objects possibly located there, impro-
 
ve the air supply. 
NOTE: If the error cause is eliminated while error codes E1 or E2 are being displayed, the appli-
ance will automatically resume operation subject to the previous setting.
With regard to all other error code indications, you will have to reset the control manually by 