Atech OEM Inc. WM100X User Manual

Page of 21
    iWEM-1000UM, Dec 30, 2010
 
Atech Technology Co., Ltd. 
7F, AAEON Building, No.43, Sec. 4, Keelung Rd, Taipei City 10607, Taiwan (R.O.C.) 
Tel: +886-2-2377-0282 
Fax: +886-2-2377-0283 
http://www.atechoem.com/
 
  Action Commands – Perform action such as scan, connect, disconnect, etc. 
  Config Commands – Set the iWEM-1000 configuration. The user needs to issue a save command to 
save the updated configuration to the flash memory. The new configuration will take effect after reboot. 
  Status Commands – See what is going on with the interface, IP status, etc. 
The user can issue ? command to list all available commands. All available commands will be printed to the 
terminal emulator in ascii format. 
 
All commands issued to iWEM-1000 must be followed by <CR> character as a command terminator. 
 
4.3. Action Commands 
The action commands are the commands to have the iWEM-1000 doing various actions other than changing 
the configuration of the module. 
 
Command 
Response 
Action and Notes 
exit Data 
mode<CR> 
Exit command mode 
ls 
<List of files><CR> 
List all files in flash 
scan [<ssid>] 
<List of APs><CR> 
Scan for infrastructure BSSs to join 
ping 
<ping_IP_addr> 
<ping response from 
the pinged 
host><CR> 
Send an ICMP echo request to the specified IP address. 
Ping the default gateway if no IP_address is specified 
set_factory_defaults OK<CR> 
Restore the configuration to factory default settings. The 
settings take effect after the module is restarted. 
tcp_connect TCP 
Connecting... 
<CR> 
Create a connection to the TCP server 
tcp_disconnect TCP 
Disconnected<CR> 
Drop the TCP connection. If the setting is TCP server, 
disconnect the TCP client connected to iWEM-1000. If the 
setting is TCP client, disconnect from the TCP server. 
restart OK: 
Restarting 
application 
now<CR> 
Restart the current application 
save OK<CR> 
Save the configuration to the EEPROM memory. The 
settings take effect after the module is restarted. 
sleep Power 
down...<CR>
Put iWEM-1000 module into sleep mode. Ground pin 5 to 
wake up module. 
tftp_get 
<tftp_server> 
OK<CR> 
Get a image from the TFTP server to upgrade firmware.