Operations and Maintenance 
RFN_3.1 Beta
  
119 
Some indications list several possible failures along with corresponding 
corrective actions. If a failure is isolated to the FRU level, the suspected 
component should be replaced with a new one. This restores the system to 
normal operation as quickly as possible. For more information, refer to section 
7.6 Repair and Technical Support.  
7.3.1 iSC-3 
This section lists troubleshooting procedures for both the iSC-3 (site controller) 
and the Environmental Alarm System (EAS). For further information, refer to the 
Gen 3 Site Controller System Manual, Motorola, 68P80801E30-O. 
Site Controller Troubleshooting 
Indication 
Possible failure 
Corrective action 
status gps MMI command 
response: Satellite tracking 
mode on all channels is less 
than 8 
Antenna, cables, surge 
arrestors, RFI 
 
Check antenna, cables, and 
surge arrestors before 
placing the site controller. 
 
If antenna installation is OK, 
suspect intermodulation 
desensitizing. 
status gps MMI command 
response: S/N numbers of 
mode 8 satellites are less than 
25 
Antenna, cables, surge 
arrestors, RFI 
 
Check antenna, cables, and 
surge arrestors before 
placing the site controller. 
 
If antenna installation is OK, 
suspect intermodulation 
desensitizing. 
ping gps MMI command 
indicates no satellites tracked. 
Open or damaged GPS and 
surge satellites tracked. 
 
Verify GPS antenna, lead-in, 
and surge arrestor. 
Slow handovers. 
Open or damaged GPS and 
surge satellites tracked. 
 
Verify GPS antenna, lead-in, 
and surge arrestor. 
 
Check for open 5 MHz cable 
and missing termination of 5 
MHz cable. 
Power LED is not lit 
No power to site controller 
 
Check power source 
 Cabling 
 
Check power cabling to site 
controller. If necessary, 
replace cabling. 
 
Site controller failure 
 
Replace the site controller. 
Site controller can’t 
communicate over Ethernet 
Ethernet cabling or 
terminations 
 
Check cabling. Verify that 
each end of the cable has a 
50-ohm termination. 
 
Site controller failure 
 
Replace the site controller. 
LOS/OOF LED is lit  
(Loss of Signal/Loss of Frame) 
T1/E1 cabling 
 
Check cabling to site 
controller. If necessary, 
replace the cabling. 
 
Site controller failure 
 
Replace the site controller. 
Yellow Alarm LED is lit 
Site controller is receiving an 
alarm from the far end. 
 
Check for proper operation 
of external site equipment.