RadioFrame Networks Inc DH2 User Manual

Page of 164
Method of Procedure 
Operations and Maintenance 
120 
RFN_3.1 Beta
 
Indication 
Possible failure 
Corrective action 
alarm from the far end. 
 
Notify far end. 
AIS LED is lit 
(Alarm Indication Signal) 
Far end equipment failure 
 
NOTE: The AIS LED is lit 
when the All Ones Keep 
Alive signal is received. 
 
Check for proper operation 
of external site equipment. 
 
Notify far end. 
FE/CRC LED is lit 
(Framing Error/CRC Error) 
T1 is no configured for ESF 
 
Configure T1 correctly. 
 Bit 
errors 
 
Check T1/E1 cabling. 
 
Check T1/E1 levels. 
 
Check for T1/E1 noise or 
crosstalk. 
 
Site controller failure 
 
Replace Site controller. 
BPV/PD LED is lit 
T1 is not configured for 
B8Zs 
 
Configure T1 correctly 
 Bit 
errors 
 
Check T1/E1 cabling. 
 
Check T1/E1 levels. 
 
Check for T1/E1 noise or 
crosstalk. 
 
Site controller failure 
 
Replace iSC-3. 
Net LED is lit 
(Network Loopback) 
The Site controller has 
received an in-band or out-
of-band loopback code, and 
is in loopback mode. 
 
Notify far end. 
Local LED is lit 
(Local Loopback) 
Front panel switch has put 
the iSC-3 into loopback 
mode. 
 
Push and hold the Sel/Loop 
switch for 2 seconds. This 
action takes the unit out of 
loopback mode. 
 
EAS Troubleshooting 
Indication 
Possible failure 
Corrective action 
EAS breaker on Cabinet 
breaker is on, but POWER 
LED (green) on EAS is not lit. 
No power connected to 
EAS. 
 
Check power source. 
 Cabling 
 
Check power cabling to EAS; 
replace cable if necessary. 
Wrong EAS response. 
Miswired modular cable 
 
Check EAS modular cabling. 
AC fail alarm 
AC input, or an open or 
disconnected alarm lead. 
 
Verify AC in put, check for 
open and disconnected 
alarm leads. 
High temperature alarm 
AC input to air conditioner 
 
Verify AC input. 
 
Site air conditioner 
 
Call for service on air 
conditioner.