RadioFrame Networks Inc DH2 User Manual

Page of 164
RadioFrame System 
Installation 
RFN_3.1 Beta
  
69 
 
Caution
 
The power supply cord is used as the main disconnect device; ensure that the 
socket-outlet is located/installed near the equipment and is easily accessible. 
 
4  Verify that the ACU is receiving power and that all cards installed in the ACU, 
front and back, are operational.  
Each card installed in the front and back of the ACU has two LEDs: Power 
and Status. All LEDs should light green.  
 
 
Figure 19 
Mount the ACU only in an EIA-standard compliant 19” rack. 
4.2.2 Connect the ACU
s to the NCU and the RFUs 
1  Connect Port 1 on the front of the ACU to the specified port (1-8) on the back 
of the NCU using an RJ45-to-RJ45 CAT 5 cable (see the following 
illustration). 
2  Verify that the ACU is connected to the NCU. 
The Link and Activity LEDs on Port 1 should both light green, and the Activity 
LED should blink rapidly indicating that the connection to the NCU is 
operating.  
3  Connect the RJ45-to-RJ45 CAT 5 cable for each RFU to the specified port  
(1-8) on the back of the ACU. 
The Link and Activity LEDs on the ports will remain unlit until each RFU has 
been installed.