RadioFrame Networks Inc DH2 User Manual
RadioFrame System
Installation
RFN_3.1 Beta
71
Figure 21
The URU can be placed or mounted on any flat surface.
3 Plug the URU into an approved power source, then, using the tie wrap
attached to the URU, secure the power cord to the unit.
4 Verify that the URU is receiving power.
The Power and Status LEDs should both light as green.
4.3.2 Changing
the
URU
Mode of Operation
On the bottom of the URU is a dip switch that is in the “Auto Sense” configuration
by default (see the following illustration). If the URU receives 48 Volts DC on
either “IN” connector, it will output 48 Volts DC on its respective “OUT”
connector. If any other mode of operation is required, set the dip switches as
follows:
by default (see the following illustration). If the URU receives 48 Volts DC on
either “IN” connector, it will output 48 Volts DC on its respective “OUT”
connector. If any other mode of operation is required, set the dip switches as
follows:
Desired Mode of Operation
DIP Switch
Number
Auto Sense Power In/Out
48VDC Output On
48VDC Output Off
1 OFF ON
OFF
2 OFF ON
OFF
3 ON
OFF
OFF
4 ON
OFF
OFF