RadioFrame Networks Inc DH2 User Manual
Method of Procedure
Installation
Installation
70
RFN_3.1 Beta
Figure 20
Connect Port 1 on the front of the ACU to the specified port (1-8) on the
back of the NCU. Connect RFUs to Ports 1-8 on the back of the ACU.
back of the NCU. Connect RFUs to Ports 1-8 on the back of the ACU.
4.3 URU
The maximum length of CAT 5 wire between RadioFrame System components is
100 meters (approximately 328’). The distance between any two components
can be extended by installing additional CAT 5 cabling and up to two URUs.
100 meters (approximately 328’). The distance between any two components
can be extended by installing additional CAT 5 cabling and up to two URUs.
# of URUs
Maximum CAT 5 Cable Length between RFS components
no URU
100 meters (approximately 328’)
1 URU
200 meters (approximately 656’)
2 URUs
300 meters (approximately 984’)
4.3.1 Installing
a
URU
Install Universal Repeater Units while wiring the RadioFrame System.
1 Find these items in each Universal Repeater Unit (URU) shipping container:
one URU, mounting screws, and one power cord with a 120VAC-to-negative
48VDC converter.
48VDC converter.
2 Place or mount the URU on any flat surface (see the following illustration).
The URU can be placed or mounted on any flat surface using the provided
mounting screws. The URU must be located within 12 feet of an approved
power source. Refer to the site documentation for the exact location of each
URU.
mounting screws. The URU must be located within 12 feet of an approved
power source. Refer to the site documentation for the exact location of each
URU.