MC-Series System Installation & Testing 
System Configuration Changes 
104 
RadioFrame Networks, Inc.
 
Remove the following terminations from the rear of each RF shelf to be added to the 
configuration: 
• 
RF Shelf 2:Tx IN B and Rx OUT B 
• 
RF Shelf 3:Tx IN C and Rx OUT C 
Reconnect the following RF cables: 
Index 
Part Number 
From 
To 
Type 
RF_2 
820-0611-20 
RF Shelf 2:  Tx IN B  
RBS 1: Tx B 
RF cable
 
RF_5 
820-0611-20 
RF Shelf 2:  Rx OUT B 
RBS 1: Rx B 
RF cable
 
RF_3 
820-0611-20 
RF Shelf 3:  Tx IN C  
RBS 1: Tx C 
RF cable
 
RF_6 
820-0611-20 
RF Shelf 3:  Rx OUT C 
RBS 1: Rx C 
RF cable
 
 
Reconnect terminations to RF Shelf 1: 
Index 
Part Number 
To 
Notes 
T2 
820-0609-00 
RF Shelf 1:  Tx IN B  
If adding RF Shelf 2 
T4 
820-0609-00 
RF Shelf 1:  Rx OUT B 
If adding RF Shelf 2 
T3 
820-0609-00 
RF Shelf 1:  Tx IN C  
If adding RF Shelf 3 
T5 
820-0609-00 
RF Shelf 1:  Rx OUT C 
If adding RF Shelf 3 
 
Remove the dust caps (RFN P/N: 546-0005-00) from cables RF_15 and RF_16 (RF Shelf 2) 
and/or RF_21, and RF_22 (RF Shelf 3). 
Remove the dust caps (RFN P/N: 546-0003-00) from TOR Tx 2 and Rx 2 (RF Shelf 2) and/or 
TOR Tx 3 and Rx 3 (RF Shelf 3). 
10 
Reconnect the following RF cables: 
Index 
Part Number 
From 
To 
Type 
RF_15 
820-0610-30 
RF Shelf 2:  TX OUT 
TOR:  Tx 2 
RF cable 
RF_16 
820-0610-30 
RF Shelf 2:  RX IN 
TOR:  Rx 2 
RF cable 
RF_21 
820-0610-30 
RF Shelf 3:  TX OUT 
TOR:  Tx 3 
RF cable 
RF_22 
820-0610-30 
RF Shelf 3:  RX IN 
TOR:  Rx 3 
RF cable 
 
11 
If the new configuration is two sectors only, RF Shelf 3 remains in the rack and must remain 
unpowered
12 
Push the new datafill load to the iSC. 
13 
Using the breakers on the PDU, turn up the BICAIC, and RBS 1 (RBS 2 and RBS 3 if 
present), and then verify that the components are operational before proceeding. 
Wait approximately 3 minutes for the following indicators: 
• 
RBS:  The STATUS LED for each group will light green in this order: A, B, and then C.  
• 
RBS:  The RADIOBLADE STATUS LEDs will light red and then green for each present 
RadioBlade. If no RB is present, the LED will not light. To verify the contents of the RBS, 
pull out the shelf (powering off is not required) and inspect the RadioBlades and their