RadioFrame Networks Inc MCSERIES10 User Manual

Page of 152
MC-Series System Installation & Testing 
System Configuration Changes 
RadioFrame Networks, Inc.
  
105 
respective status LEDs. Reinsert the RBS. To do this, press up on one side rail locking 
arm and press down on the other side rail locking arm, and then push the unit into the 
rack (see the following illustration). 
• 
BIC CRIC and AIC CRIC:  The POWER and STATUS LEDs will light red and then green. 
All other BIC and AIC card LEDs will light green. 
14 
Using the breaker on the PDU, turn up RF Shelf 1 and RF Shelf 2.  
Do not turn up RF Shelf 3. Verify that RF Shelf 1 and RF Shelf 2 are operational before 
proceeding. 
The POWER and ALARM LEDs on the front of each RF shelf will light green. 
15 
Complete the procedure in section 7.8 TOR Tx Measurement Procedure. 
8.4  Removing a Sector 
To remove a sector from the MC-Series System, disconnect an RF shelf. To remove one sector, 
disconnect RF Shelf 3. To remove two sectors, disconnect both RF Shelf 2 and RF Shelf 3. Refer 
to Appendix C Cabling Diagrams: 3-Sector Configuration. 
Have the site configuration available. 
In System Manager, display the iDEN Configuration page, and change the cabinets and 
positions (and quad BRs or adjacent channel assignments) as required for the new 
configuration (refer to the site datafill). 
Power down all RFN equipment in the following order using circuit breakers on the PDU: 
• 
BIC 
• 
AIC 
• 
RBS 1 (RBS 2 and RBS 3 if present) 
• 
RF shelf 1, 2, and 3 
Remove the following terminations from RF Shelf 1: 
• 
RF Shelf 2: Tx IN B and Rx OUT B 
• 
RF Shelf 3: Tx IN C and Rx OUT C 
Reconnect terminations to: 
• 
RF Shelf 2: Tx IN B and Rx OUT B 
• 
RF Shelf 3: Tx IN C and Rx OUT C 
Reconnect the following RF cables to RF Shelf 1: 
Index 
Part Number 
From 
To 
Type 
RF_2 
820-0611-20 
RF Shelf 2:  Tx IN B  
RF Shelf 1:  Tx IN B 
RF cable
 
RF_5 
820-0611-20 
RF Shelf 2:  Rx OUT B 
RF Shelf 1:  Rx OUT B 
RF cable
 
RF_3 
820-0611-20 
RF Shelf 3:  Tx IN C  
RF Shelf 1:  Tx IN C 
RF cable
 
RF_6 
820-0611-20 
RF Shelf 3:  Rx OUT C  
RF Shelf 1:  Rx OUT C
 