5. Resetting a SAFE-O-TRONIC with the "ResetKey"
Clearing a SAFE-O-TRONIC may be necessary for example if a mistake was made in initialising
(e.g. wrong cabinet number) or if a SAFE-O-TRONIC needs to have a different configuration.
NOTE
The ResetKey is only accepted by the SAFE-O-TRONIC if it is unlocked!
Operation:
1.  Activate megalock (push rotary knob)
2.  You have 8 seconds to hold the ResetKey in front of the rotary knob in the sensing zone of
the SAFE-O-TRONIC antenna.
 
Once the parameters in the SAFE-O-TRONIC have been cleared, the SAFE-O-TRONIC
acknowledges the process by causing the green LED to come on for a brief time followed
by simultaneous flashing of the green and red LED.
3.  Now the SAFE-O-TRONIC can be reconfigured with a SetupKey
(see: 4.2. Configuring the SAFE-O-TRONIC with the "SetupKey").
6. Replacing a SAFE-O-TRONIC
If it becomes necessary to replace a SAFE-O-TRONIC, the new SAFE-O-TRONIC must first:
1.  be configured with the megalock number and other parameters using the SetupKey
(see: 4.2. Configuring the SAFE-O-TRONIC with the "SetupKey") and
2.  be actuated with a MasterKey to ensure that the new SAFE-O-TRONIC accepts only
MasterKeys having the currently valid MasterKey-Generation.