7. Battery
The battery in the SAFE-O-TRONIC is designed for at least 40 actuations daily within a period of 3
years. The time when the battery needs to be replaced will depend however on the self-discharging
of the battery and by climatic effects, especially cold temperatures.
To summarize, the time to replace the battery depends on the following factors:
1.  the number of actuations,
2.  how long the battery has been installed, and
3.  the ambient temperature in which the SAFE-O-TRONIC is operated.
7.1. Battery replacement
The battery compartment integrated into the lock body is only accessible when the cabinet is
opened, and can only be opened using a special screwdriver (Type: 
ID ML.SSD-A)
.
  After opening the battery compartment, disconnect the discharged battery pack at the connector
and plug in the new battery pack.
  Once the new battery pack has been installed, the SAFE-O-TRONIC is ready for immediate
use. Use the ClockSetKey to set the internal real time clock after the battery was replaced or
disconnected.
  The discharged battery pack must be properly disposed of according to prevailing envi-
ronmental regulations!
NOTE:
 
The discharged battery pack must be properly disposed of according to prevail-
ing environmental regulations!
 
Use only batteries recommended by the manufacturer (Type: ID ML.BP-A). The
use of non-approved batteries may cause malfunctions and result in damage to
the SAFE-O-TRONIC.
8. Service / Maintenance
The mechanical parts of the  SAFE-O-TRONIC are maintenance-free. Under no circum-
stances use mineral oil based lubricants or greases.
Clean only using non-sticky, non-residue cleaners and disinfectants. Do not use harsh sol-
vents, acids or lye for cleaning.
NOTE:
Cleaning with water-jet or steam jet could occur irreparable damage!