Installation
Schulte- Schlagbaum AG
Page 7 of 14
SOT-manual.DOC
4.2. Configuring the SAFE-O-TRONIC with the "SetupKey"
The SetupKey is used to configure the System-ID, the cabinet number, the operating mode and the
group number in the SAFE-O-TRONIC. Only than can the SAFE-O-TRONIC be used in the sys-
tem.
An already configured SAFE-O-TRONIC will no longer accept the SetupKey. To change the con-
figuration of a SAFE-O-TRONIC, the latter must first have been cleared using a valid ResetKey.
CAUTION:
Use only a SetupKey having the correct Group No. and System-ID.
Operation:
1.  Set the parameters on megalock Admin or on the megalock Programmer and program
them into the SetupKey.
Set the following data:
- Next SAFE-O-TRONIC number to be programmed (cabinet number)
- Operating mode (free cabinet select / fixed cabinet assignment / multi-user mode)
- Group No. to which the SAFE-O-TRONIC is to be assigned.
2.  Go to the first SAFE-O-TRONIC with the SetupKey, waken up the lock and configure it by
presenting the SetupKey.
The SetupKey must be held in front of the rotary knob until the SAFE-O-TRONIC
acknowledges this by causing the green LED to flash.
3.  Now the next SAFE-O-TRONIC can be configured with a sequential cabinet number.
Assigning the megalock number is done according to the same principle.
Once the SAFE-O-TRONIC has uploaded the
number, it increments the number on the Set-
upKey by +1.
Now the number for the next  SAFE-O-
TRONIC
 is stored on the SetupKey, and as
many megalocks as desired can be initialized
with a sequential number without having to
first reprogram the SetupKey.
NOTE:
If a gap in the sequential numbering of the
SAFE-O-TRONICs is desired, such as at
the end of a row of cabinets, the new cabi-
net number will have to be programmed
into the SetupKey.