6 HARDWARE INTERFACES
6.1 6-pin connector 
Figure 4:
View of the 16-pin connector pin assignments
6.1.1 Pin assignment on the 6-pin connector
 
 
PIN
NAME
I/O
DESCRIPTION
LEVEL
1
RxA 
I
RS232   serial   interface   (receive   data)   for   direct 
connection . If not used leave open.
V24, 
±
12 V
2
TxA 
O
RS232 serial interface   (transmit data) for direct 
connection. If not used leave open.
V24, 
±
12 V
3
+IN
I
Power supply input (Input 7). The power supply 
must be able to meet the requirements of current 
consumption.   Care   must  be   taken   so   that   the 
operating   voltage   applied   to   the   terminal   stay 
within   the   voltage   range.   Applying   a   voltage 
outside of the voltage range can damage the unit.
V
I
 = +10.8 ... +35.0V;  Imax ≤ 2A
4
GND
-
Ground.
0 V
5
IGN
I
General  purpose  input.   Either  connect  it to  the 
vehicle ignition and use it for journey START and 
STOP   reports   or   connect   it   to   the   operating 
voltage   +IN   and   with   the   help   of   an   external 
switch you are able to wake up the BOLERO-LT 
device from  IGN-Sleep  mode  (sending  into  the 
IGN-Sleep   mode   this   pin   should   be   low   while 
awaking from this mode requires a HIGH signal)

See also chapter 
HIGH ≥+10.8 .. +35.0 V DC; LOW = 0V
6
IO1
I/O
Individually   software   configurable   as   digital   or 
analog input or digital output.
In the software it corresponds to  IO0  if used as 
input or IO4 if used as output.
Analog IN :  Up to 35.0 V DC/10 bits resolution
IN: +0 ... +35.0 V DC (High and Low programmable 
by the software)
OUT: 100 mA @ +10.8 … +35.0 V DC
Table 8: