Falcom GmbH BOLERO-LT User Manual

Page of 30
BOLERO-LT Hardware Description
Version 1.0.0
6.1.2 Special pin description
 
 
For the IO lines that can work as input or output the corresponding output of this pin 
has to be set to high (with PFAL command “
$PFAL,IO
4
.Set=high”
), otherwise 0V will be 
measured
 (and the device could be damaged).
6.1.2.1 Analog input (6)
Analog   voltage   up   to   35.0   V   with   10   bit   resolution   can   be   processed   and 
remotely evaluated by a server application. Pull-up resistor to a constant input 
voltage allows for resistive transducers to ground, e.g. fuel sensor or thermistors. 
Because   the   pin  6  can   operate   either   as   digital   or   analog,   it   has   to   be 
configured and calibrated for such purposes before using.
To use these IOs as analog inputs, the following configuration is required in the 
software. 
PFAL,IO
0
.Config=AI,2,11 
PFAL,IO
0
.Config=DI,3,6 
where 0 is the index corresponding to IO1 (pin 6). The strings AI and DI are identifiers 
for analog and digital input respectively. While the value after strings e.g.  3  and  6  are 
min. and max. voltages that will be used to generate Low and High events respectively.  
Detailed   information   can   be   found   in   software   manual  
steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf
6.1.2.1.1Connection example using IO1 as analog inputs:
This pin can be connected to a temperature sensor (a NTC resistor for instance). 
Therefore, you can set a low and high temperature alarm. Passage through 
these thresholds will trigger an alarm. As alarm type you can use an SMS or a 
TCP with  GPIOP  as attachment protocol. The SMS contents can be sent to a 
mobile phone. An application example is shown in figure below:
Figure 5:
Connection example for analog input (IO1)
This circuit example is only an illustration to show the aim of the analog input.
This confidential document is a property of FALCOM and may not be copied or circulated without previous permission.