BOLERO-LT Hardware Description
Version 1.0.0
6.1.2.2 Digital Input (pin 6)
This pin is a high active when is used as digital input, so you can set V
IN(LOW)
 and 
V
IN(HIGH)
 to any levels within the range from +0 to +35.0 VDC. The High and Low 
levels have to be set by using the PFAL command (e.g. 
PFAL,IO
0
.Config=DI,3,6
)
  - 
where 0 is the index corresponding to IO1 (pin 6). While the value 3 and 6 are min. and  
max.   voltages   that   will   be   used   to   generate   Low   and   High   events   respectively. 
Detailed   information   can   be   found   in   software   manual 
steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf
.
The figure below illustrates how to connect these pins and use them as digital 
inputs.   When   an   input   is   activated,   BOLERO-LT   can   release   an   alarm   (for 
instance a SMS, TCP or GSM data connection). The alarm type and the alarm 
text   are   user   dependent.   These   inputs   can   be   configured   by   using   the 
“steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf”  
manual. Both inputs 
can be connected as shown below:
Figure 6:
Connection example for digital input (IO1)
A completed circuit example for all inputs is attached in section 
This confidential document is a property of FALCOM and may not be copied or circulated without previous permission.