6.1.2.2 Digital Input (pin 6)
This pin is a high active when is used as digital input, so you can set V
IN(LOW)
and
V
IN(HIGH)
to any levels within the range from +0 to +35.0 VDC. The High and Low
levels have to be set by using the PFAL command (e.g.
PFAL,IO
0
.Config=DI,3,6
)
-
where 0 is the index corresponding to IO1 (pin 6). While the value 3 and 6 are min. and
max. voltages that will be used to generate Low and High events respectively.
Detailed information can be found in software manual
“steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf“
“steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf“
.
The figure below illustrates how to connect these pins and use them as digital
inputs. When an input is activated, BOLERO-LT can release an alarm (for
instance a SMS, TCP or GSM data connection). The alarm type and the alarm
text are user dependent. These inputs can be configured by using the
inputs. When an input is activated, BOLERO-LT can release an alarm (for
instance a SMS, TCP or GSM data connection). The alarm type and the alarm
text are user dependent. These inputs can be configured by using the
“steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf”
manual. Both inputs
can be connected as shown below:
Figure 6:
Connection example for digital input (IO1)