AlarmView™ System User’s Guide 
 
 
 
{insert part #} Page 31 
 
 
7. Wait for receipt of a “Programming OK” status message, 
then tap Exit button to return to SysMgr. 
 
The complete Survey Paging procedure is detailed in Section 5: 
Testing and Periodic Maintenance, “Transmitter Range Test,
” in 
this manual. 
 
 
Changing Global System Parameters 
 
An AlarmView System is defined by a common transmission 
frequency and a pager Global Cap Code. All transmitters and 
pagers within an AlarmView System must have the same 
Transmission Frequency (MHz), Baud Rate (bps), and Global 
Pager Cap Code. 
 
The Reminder Page Delay Interval is also intended to be the 
same value for all transmitters in the system. 
 
!
!
!
!
!
!
 
 
 
 
 
 
You can retrieve the current configuration from one transmitter, 
and change the parameters in the programmer once. Then 
program the changes into all transmitters in the system one 
at a time.
 
 
Changing Frequency, Baud Rate, and Global Cap Code 
 
1. From SysMgr, tap Start button and tap Install Program. 
 
2. Enter password. Alarms screen will be displayed. 
 
3. Tap Pagers tab to enter Pager configuration screen. 
 
{Insert pager configuration screen (Figure 6-8)} 
 
Pager Configuration Screen 
 
4. Turn on any transmitter in system, and aim programmer 
infrared port directly at infrared port on front of transmitter.