Data Critical Corporation AVTS1010 User Manual
AlarmView™ System User’s Guide
{insert part #} Page 38
range button}. Programmer will display “Survey Command Sent”
status message and survey paging will begin.
status message and survey paging will begin.
4. Turn on pager(s) assigned to transmitter. Qualified personnel
should be ready to walk the dimensions of the care unit. If you
use more than one pager, keep them at least 4’ apart to avoid
interference.
use more than one pager, keep them at least 4’ apart to avoid
interference.
5. To start survey paging, aim programmer infrared port directly at
port on front of transmitter and tap SVY button (in upper left
corner of screen). Programmer will display “Survey Command
Sent” status message and survey paging will begin.
The transmitter will transmit a series of consecutively numbered
pages (1, 2, 3, 4, etc.). Assigned pagers in survey will display the
following message for each page:
corner of screen). Programmer will display “Survey Command
Sent” status message and survey paging will begin.
The transmitter will transmit a series of consecutively numbered
pages (1, 2, 3, 4, etc.). Assigned pagers in survey will display the
following message for each page:
Bed: 1234
Survey Page #xxx*
Survey Page #xxx*
* XXX is the number of the survey page in the sequence.
6. To stop transmitter before all survey pages are sent, press and
release the On/Off button on transmitter once.
7. Walk slowly around the unit, observing the sequentially
numbered pages. Pay special attention to elevator banks,
columns, metal doors, double doors, and areas with plaster
construction. Dead spots or out of range conditions will be
identified by missing survey page numbers in the sequence. A
corrupt or partial or incomplete page is the same as a missing
page.
columns, metal doors, double doors, and areas with plaster
construction. Dead spots or out of range conditions will be
identified by missing survey page numbers in the sequence. A
corrupt or partial or incomplete page is the same as a missing
page.
!
!
!
If the system you are testing contains more than one transmitter, the
transmitters should be able to detect each other to avoid corrupt or
missing pages if transmitters attempt to send messages at the same
time.
transmitters should be able to detect each other to avoid corrupt or
missing pages if transmitters attempt to send messages at the same
time.