Senstar LM100 calibration
Page 56
Senstar LM100 Product Guide
Defining the luminaire segments and alarm zones
Each Senstar LM100 system can be organized into up to 50 segments. The defined segments can 
then be assigned to as many as 50 distinct alarm zones. Use the UCM software to organize the 
luminaires into segments, according to the site’s requirements for alarm detection and response. 
The segments are then assigned to zones to fit the alarm zone layouts for display and control, and 
routine lighting. Once the segments and zones are setup, you adjust the Threshold independently 
for each defined segment to match the sensors response to the fence conditions and to increase 
or decrease the detection sensitivity for that segment. 
Figure 51: LM100 Config tab
Note
Luminaires must be numbered sequentially in the Head Sequence list 
to be assigned together in a segment (e.g., heads 4, 5, 6, 7 could be 
assigned to a segment, but heads 4, 5, 6, 9 could not).
Note
Any luminaires that are used only for lighting purposes (e.g., to light a 
walkway or entrance) should be assigned to a segment in which the 
threshold is set to maximum. This enables routine scheduled lighting 
control and disables alarm detection. 
Event Window setting
Event Count setting
Alarm Window setting
Threshold adjustment arrows
recorded Profile (gray line)
Threshold set slightly below profile (red line)
(period that must lapse before a subsequent
Event is added to the Event count)
(number of Events that will cause an alarm)
(period in which a 
Target Filter
Comm Channel
Normal Light Control (brightness)
Auto Light Control
(alarm response)
Segment definition and control settings
(setup segments, zones and alarm relays)
Sequence button (setup head sequence)
Profile button (record Sensitivity Profile)
Split button (divide selected Segment)
Delete button (delete selected Segment)
subsequent Event must occur)
(use to adjust all thresholds simultaneously)
Segment setting window