Senstar LM100 calibration
Senstar LM100 Product Guide
Page 57
Defining the initial zone
When the sequencing procedure is completed, the segment setting window on the Config tab will 
have one segment which is assigned to zone 1 (see 
).
Defining the segments
The first segment, Segment 1, Zone 1 includes Head: 1 to 100 (even if the system does not 
include 100 luminaires). Select the Split button and there will be 2 segments, with both assigned to 
Zone 1. Segment 1 includes luminaires 1 - 50 and Segment 2 includes luminaires 51 - 100. (Each 
time you select the split button, you divide the selected segment into two equal sections.) Next, 
specify the luminaire that will be the start point of the second segment. (e.g., If the first segment 
will include luminaires 1 to 7, then the second segment will start with luminaire 8.) Next, assign the 
defined segment a zone number for alarm reporting and lighting control. Each LM100 can include 
up to 50 segments and up to 50 distinct alarm zones. 
1. Below the segment setting window, select the Split button.
The selected segment is divided into 2 sections, the white section is the currently selected 
segment. 
2. Left-click the boundary line and drag the zone boundary to the appropriate point in the 
segment setting window (or use the Head: field spin control to enter the number of the 
luminaire that represents the start of the currently selected segment).
3. Use the Zone: spin control to assign the segment to an alarm zone (label the zone according 
to the site plan; multiple segments can be assigned to one zone).
4. Repeat this procedure to define each luminaire segment and zone, as specified in the site 
plan.
5. Save the UCM file and download the configuration data to the gateway.
Note
You can use the horizontal magnification button to provide a closer 
view. 
Figure 52: Defining luminaire segments
magnification buttons
use the Delete button to merge the selected
segment with the preceding segment
segment assigned to Zone 5 has threshold set 
the assigned Zone label is centered at the top
of the segment
to maximum (255) to enable scheduled light
control and disable alarm detection