Note: The LPM is either RS-232 or RS-422. The loop-back test will only work if the appropriate loop-back 
connector is used.  
2.  Connect the appropriate loop-back connector to the COM port. In the RS-232 loop-back connector, the Tx and 
Rx signals are connected. In the RS-422 loop-back connector, the Tx+ and Rx+ signals are connected and 
the Tx- and Rx- signals are connected. The LPM RS-232 pin outs are shown on page 260; the LPM RS-422 
pin outs are shown on page 261. 
3.  Select the 
Diagnostics link on the left side panel of the CTM web interface. 
Result: The following screen appears. 
 
4.  Select the Serial port loop-back test link. 
Result: The following screen appears.