 Multi-Protocol Reader Ver. 2: Maintenance Instructions  
 
Confidential 
UM
 
360450-210: A7 
Page 199 of 282 
© Kapsch TrafficCom Canada Inc. 2013 
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom  Canada Inc. and are issued in strict 
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or 
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc. 
 
 
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 
 
10/31/2013 7:56 
Kapsch TrafficCom 
 
5.  Select the 
LPM COM port from the Test Enable/Disable drop-down box.  
6.  Click the 
Perform Test(s) button. 
Result: The test result displays. 
7.  If the test passes, the LPM COM port is functional.  
8.  If the test fails, ensure the correct loop-back connector was used, then, replace the CTM and repeat steps 4 
9.  If the test fails again, replace the LPM. 
Testing the Synchronization Circuit  
This first part of this test checks the functionality of one Reader’s SPM. The second part of this test 
checks the Synchronization wiring from one Reader’s SPM to the synchronization circuit terminal block  
Prerequisites: 
  At least one RF module installed in the Reader. 
  Both Primary and Secondary CTMs are configured the same. 
  Synchronization enabled