Digital Security Controls Ltd. 005132XS433 User Manual

Page of 28
7
4.1 Program Zones and Partitions
Now that you have enrolled the wireless devices, you should complete all zone
programming on the system. Although the exact programming required varies
depending on which control panel the PC5132 is connected to, you should check
that the following programming areas are completed correctly for each wireless
zone:
• Enable zones and/or assign zones to one or more partitions (programming
sections [201]-[209]).
• Program the definition for each zone (programming sections [001]-[004]).
• Enable the wireless zone attribute for each wireless zone (PC585, PC1565,
PC5020, PC501X v2.0 and up only) (sections [101]-[132]).
See your system 
Installation Manual, for more information on each of the above
programming sections.
4.2 Enable PC5132 Supervision
The control panel will supervise the PC5132 receiver via the Keybus after at least
one device has been enrolled on the module (see section 3.2 “Enrolling Wireless
Devices”).
To activate module supervision, after you enroll the first device(s):
1. Exit and then re-enter Installer Programming
2. Enter programming section [902]. Wait approximately 1 minute.
3. To exit press [#].
The system will generate a General System Supervisory trouble if the module is
removed from the Keybus. If you need to remove the PC5132 module from an
existing system, you will have to disable supervision of the PC5132.
NOTE:  Deleting all devices from the PC5132 or defaulting the PC5132 will cause
a PC5132 supervisory fault
To disable PC5132 supervision:
1. Disconnect the PC5132 from the Keybus
2. Enter [
✱][8][Installer’s Code]
3. Enter [902]. The control panel will clear all supervision and re-scan the system for
connected modules. The scan will take approximately one minute.
4. To exit press [#].
To review which modules the control panel is currently supervising:
1. Enter [
✱][8][Installer’s Code]
2. Enter [903] to display all modules. On LED keypads, light [17] will indicate
that the PC5132 is present on the system. On LCD keypads, scroll until the
module name appears on the display.
3. To exit press [#].
S E C T I O N  4
Other Programming