Digital Security Controls Ltd. 005132XS433 User Manual

Page of 28
9
O T H E R  P R O G R A M M I N G
1. Enter [
✱][8][Installer’s Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132 Module Programming.
3.
Turn ON section [90], option [7].
4. To exit press [#].
4.5 PC5132 Software Default
Returning the PC5132 programming to factory default settings is a quick way to
remove all the enrolled devices from the system and reset all the programming in
section [804].
NOTE: Performing this procedure will not change any programming sections ex-
cept [804]. Resetting the control panel to factory default settings will not return the
PC5132 module to factory default settings.
To restore the PC5132 programming to the factory default settings:
1. Enter [
✱][8] [Installer’s Code].
2. Enter programming section [996].
3. Enter the Installer’s Code, followed by [996] again. The software for the
PC5132 will be restored to its factory default settings.
4. To continue programming the unit, exit Installer Programming by pressing
[#] and then re-enter Installer Programming by entering [
✱][8] [Installer’s
Code].
For instructions on restoring the default programming of the control panel or any
other connected module, see your system 
Installation Manual.
4.6 Deleting Wireless Devices
To remove a wireless device from the system, follow the guideline for enrolling a
wireless device (see section 3.2). Program the ESN as [000000]. The wireless
device for the zone will be removed.
NOTE: You may need to remove power from the panel in order to clear troubles
caused by deleted zones.
Now that you have completed all PC5132 related programming, you can test and
mount the receiver and devices. See section 5 for more information.