The NT9010 will only announce “Service Required”. If the control unit announces 
this trouble, users can press [1] to expand the troubles. The user should call for 
assistance. The specific trouble will be logged in the event buffer.
AC Failure: AC power is no longer being supplied to the NT9010 control unit. To 
conserve power, when there is an AC Failure all lights will turn off, except for the 
flashing System light.
Telephone Line Monitoring Trouble (TLM): There is a problem with the tele-
phone line (See 2.3.15 Telephone Line Monitoring (TLM) on page 53.) 
Failure to Communicate (FTC): The communicator failed to communicate with 
any of the programmed telephone numbers (see 2.3.8 Communicator Dialing on 
page 41). 
Zone Fault (including Fire Zone): A zone on the system is experiencing trouble. 
This means that a zone could not generate an alarm on the system if required to do 
so (e.g. a fire zone is open, or a supervisory fault on a wireless zone). When a zone 
fault occurs, the unit will start to beep. Press [5] while in Trouble mode to hear an 
announcement of the affected zones.
NOTE:
 A Fire zone trouble will be generated and announced in the 
armed state. 
Zone Tamper: The tamper switch is open on a wireless device. When a tamper 
condition occurs, the NT9010 will start to beep (if the system is armed, an alarm 
will occur). Press [6] while in the Trouble mode to hear an announcement of the 
affected zones. If a zone is tampered or faulted, it must be fully restored to clear 
the trouble. If a smoke detector is tampered, the Ready light will remain on and the 
system can be armed.
NOTE:
Once a zone is tampered or faulted, it must be completely 
restored before the trouble condition will clear.
Device Low Battery: A wireless device has a low battery condition. Press [7] one, 
two, or three times to hear which devices are experiencing battery failure. The fol-
lowing will occur:
Keypad beeps:
NT9010 Announces:
Press [7]
1
Zones with low batteries 
Press [7] twice
3
Wireless keys with low batteries 
Loss of System Time: When the system is powered up, the internal clock needs to 
be set to the correct time. This trouble is cleared when an attempt is made to reset 
the clock.
[*] [3] Alarm Memory
If there is an alarm in memory when the system is disarmed, the System light will be 
on. Press [✱][3] to enter the alarm memory mode. The NT9010 system will 
announce the alarms that are in memory by zone number or label. For example:
“There is 1 alarm in memory. Fire Zone. To exit, Press ‘#'.”
Press [#] to return to the “Ready” mode. Alarm Memory is cleared when the system 
is armed.