Digital Security Controls Ltd. 01NB9010 User Manual

Page of 68
S e c t i o n   2. 2:  C h an g i n g   H o w   t h e   N T 90 1 0   W o r k s   F o r  U s e r s
2 9
[*] [4] Door Chime On/Off
Users can turn the Door Chime feature on or off by pressing [✱][4]. If the door 
chime feature is enabled the keypad will beep 6 times rapidly when a zone is 
opened and closed. The system will only do this for zones with the Door Chime 
Attribute
 enabled and if the door chime feature is enabled (see 2.3.2 Zone 
Attributes 
on page 38)
You can have the NT9010 system announce the names of zones when they are 
opened or closed by turning on the Verbal Chime feature. Please see 2.2.3 Voice 
Prompt Interface
 on page 22.
Door Chime Zone Attribute . . . . . . . . . . . . . . . . Sections [101] to [132], Option [3]
Verbal Chime Enabled/Disabled . . . . . . . . . . . . . . . . . . . .  Section [017], Option [2]
Verbal Chime for Zone Openings . . . . . . . . . . . . . . .Section [807]-[002], Option [2]
Verbal Chime for Zone Closings . . . . . . . . . . . . . . . .Section [807]-[002], Option [3]
[*] [5] Programming Access Codes
All access codes can be programmed using the [✱][5] command. For complete 
instructions on programming access codes, see the NT9010 User’s Guide (“Pro-
gramming Access Codes”). For information on access code attribute programming, 
see 2.2.2 Access Codes on page 20.
[*] [6] User Functions
To program user functions, perform the following:
1. Press [✱] [6] [Master code]. The keypad will flash the ‘System’ light. 
2. Press the number [1] to [7] for the item to be programmed.
• [1] - Time and Date
See the NT9010 User’s Guide for instructions on setting the time and date 
(“Setting the Time and Date”).
• [2] - Auto-Arm Enable/Disable
Enter [2] to enable (three keypad beeps) or disable (one long beep) the auto-
arm feature.
• [3] - Auto-Arm Schedule
Enter [3] to change the auto-arm time. 
Enter the auto-arm time in 24-hour format (i.e. enter a 4-digit number in 
[hhmm] format).
• [4] - System Test
For step-by-step instructions on performing a system test, see the NT9010 
User’s Guide
 (“Full System Test”). When [4] is pressed the system will perform 
the following:
sound the alarm output for two seconds 
light all lights on the keypad
sound the keypad buzzer for two seconds 
test the NT9010 battery
send a System Test Reporting code, if programmed (see 2.3.12 
CommunicatorReporting Codes 
on page 47).
• [5] - Enable DLS (Downloading)
When [5] is pressed the system will turn on the downloading option for 1 or 6