Digital Security Controls Ltd. 01NB9010 User Manual

Page of 68
S e c t i o n   2. 2:  C h an g i n g   H o w   t h e   N T 90 1 0   W o r k s   F o r  U s e r s
3 1
2.2.10 Function 
Keys
There are eight function keys on the NT9010 labelled Stay, Away, Chime, Exit, Sta-
tus, Volume, Record and Playback. The operation of these keys is described below. 
Users can activate each function by pressing the key.
The programming of any function key on the NT9010 may be changed to any of 
the options listed below. To change the programming of a function key:
1. Enter [✱][8][Installer’s Code].
2. Enter section [807].
3. Enter [000] for function key programming.
4. Enter the 2-digit code for the function you want to program for each key. (Each 
function is described below.)
5. When you are finished, press [#] to exit.
[00] - Null Key
The key is not used and will perform no function when pressed.
[01] - [02] For future use
[03] - Stay Arm
Arms the system in Stay mode. All Stay/Away type zones will be automatically 
bypassed. Delay type zones will provide entry and exit delay. The Quick Arm fea-
ture must be enabled for this key to function (Section [015], Option [4]). If Quick 
Arming is not enabled, the user must enter a valid access code after pressing the 
function key in order to arm the system in the Stay mode.
[04] - Away Arm
Arms the system in Away mode. All Stay/Away type zones will be active at the end 
of the exit delay. Delay type zones will provide entry and exit delay. The Quick Arm 
feature must be enabled for this key to function (Section [015], option [4]). If Quick 
Arming is not enabled, the user must enter a valid access code after pressing the 
function key in order to arm the system in the Away mode.
[05] - [
]+[9] No-Entry Delay Arm
After this function key is pressed the user must enter a valid access code. The sys-
tem will arm and remove entry delay from the system when the exit delay expires 
(see  [*] [9] Arming Without Entry Delay on page 30).
[06] - [
]+[4] Door Chime On/Off
Pressing the key will toggle the Door Chime feature ON or OFF. One solid beep 
means the feature has been disabled, three short beeps means it has been enabled.
[07] - [
]+[6]...[4] System Test
This function key provides the user with a simple method for testing the system 
(see  [*] [6] User Functions on page 29).
[08] - [
]+[1] Bypass Mode
This function key provides the user with a simple method for entering the Bypass 
Mode. If an access code is required it must be entered before bypassing can be per-
formed (see  [*] [1] Zone Bypassing on page 27).