Controls and Indicators
NOTE: Multiple trouble conditions are displayed (flashed) in sequence.
Red LED
The red LED will flash to provide event transmission status for the following
events:
1 Flash
1 Flash
2 Flashes
Enroll button held down for 2 seconds
Event transmitted to cellular network
Event acknowledged by Connect 24.
Green LED
The green LED will light continuously if the (RSSI) signal is acceptable. If signal
strength is not acceptable the LED will turn OFF. Detailed information on signal
strength can be accessed by momentarily pressing and releasing the enroll
button. The green, yellow and red LEDs will light to indicate the range of signal
strength. Refer to Section 2 Step 3.
3.2 Enroll Button (see figure 2)
The Skyroute CL3050 Enroll button is located on the outside of the plastic hous-
ing directly below the status LEDs. The enroll button performs three functions. 
Pressing and releasing this button momentarily during the first 15 seconds 
of power up will toggle between Mode 1 and Mode 2 to enable mode 
selection.
Pressing and releasing this button momentarily at any time after the power 
up sequence will display the detailed RSSI status indicated above.  
Holding this button down for a period of 2 seconds continuously will cause 
the Skyroute CL3050 to send a test transmission to Connect 24, this long 
debounce will be indicated by the red LED flashing once.
3.3 Terminal Connections (see figure 2)
RED
10.6-14V
DC
 Positive Input or 10.6-14V
AC
NOTE:  12V
DC
 is required for programming or for operation with a
PC5108 zone expander. Mode 1 and Mode 2 may be operated with an
AC Supply.
BLK
10.6-14V
DC
 Ground or 10.6-14V
AC
YEL
Mode 1* - The YEL terminal functions as the Bell input.
Mode 2 - This terminal functions as the zone 1 input.
Mode 3  - This terminal connects to the YEL Keybus terminal when
using a PC5108 zone expander or PowerSeries keypad.
GRN
Mode 1* - The GRN terminal functions as the TLM Trouble input. 
Mode 2 - This terminal functions as the zone 2 input. 
Mode 3  - This terminal connects to the GRN Keybus terminal when
using a PC5108 zone expander or PowerSeries keypad.
COM
Mode 1* - This terminal functions as the common terminal for the Bell
Input on the YEL terminal, the TLM trouble input on the GRN terminal
and the Trouble Output on the PGM terminal. 
Mode 2 - This terminal functions as the common terminal for zone 1
(YEL) and zone 2 (GRN). 
Mode 3 - This terminal functions as the common terminal for the
Trouble Output
NOTE: Mode 1 is not intended for UL Installations.