Digital Security Controls Ltd. 05SKYCL User Manual

Page of 28
8
System Programming
Section 5: System Programming
The Skyroute CL3050 is programmed using any PowerSeries keypad. Refer to    
Section 1.1 Specifications.
NOTE:  Power down the Skyroute CL3050 when connecting or removing other
Keybus modules from the system. If the Skyroute CL3050 is connected to a con-
trol panel (mode 1), the control panel must also be powered down.
1.
Connect keypad Keybus connections to the RED, BLK, YEL and GRN termi-
nals of the Skyroute CL3050.  
2.
Connect a +12VDC supply across the RED and BLK terminals.  
Upon detecting the keypad on power up, the Skyroute CL3050 will begin 
driving Keybus and will blank the keypad with all LEDs and icons off. 
NOTE: The red LED on the Skyroute CL3050 will flash continuously if a
keypad is detected.
3.
Press the star [*] key to gain access to the programming section. 
Programming is done with a 2-digit section entry.  When programming is 
complete, power down the Skyroute CL3050 and remove the keypad.
Section 6: Programming Descriptions
[01] Zone 1, 2 Definitions
Modes 2, 3
When the Skyroute CL3050 is in Mode 2 or 3, there are 14 options that can be 
programmed as zone types.  All of the zone types with the exception of 00 (null 
zone), 13 (CL3050 communications zone) and 14 (trouble zone) are straightfor-
ward.  Since all the zones are 24-hour type zones, selecting any listed zone type 
will simply select which identifier should be used for reporting the alarm.  Pro-
gramming a zone as 00 (null zone) will disable the zone input on the Skyroute 
CL3050 or PC5108 hardware.  Programming any zone as type 13 (CL3050 com-
munications zone) will disable all communications unless that zone input is closed 
(short condition). Programming a zone as 14 ( trouble zone) will enable an addi-
tional reporting code to be sent with the daily/weekly test transmission (if 
enabled). If all zones are restored and there are no trouble conditions present on 
the Skyroute CL3050, a periodic test transmission code (RP00) will be sent. other-
wise a periodic test off-normal code (RY00) will be sent instead.
NOTE: Do NOT  program more than 1 CL3050 communications zone or trouble
zone on the Skyroute CL3050.
Default
 - [01] zones 1 & 2
RED    BLK
YEL    GRN   COM   PGM
+12 V
DC
Ground
To Keybus
Connections
on Keypad
Not Connected