Digital Security Controls Ltd. 05SKYCL User Manual

Page of 28
12
Programming Descriptions
.
NOTE: A relay may be required for proper operation in other configurations. 
See paragraph 3.3 Terminal Connections.
Option 1 - Low battery
All Modes
If the battery voltage drops below 5.72V
DC
 a trouble will be indicated until the
battery voltage rises to 5.87V
DC.     
Default - ON
Option 2 - Input Supply Failure
All Modes
If AC power is absent or if DC power drops below 8.8V
DC  
on the RED and BLK
terminals, this
 
trouble is indicated. Default - ON
Option 3 - Zone Fault/Tamper (DEOL Only)
Modes 2, 3
A trouble will be indicated if any zone reports a fault or tamper condition. In Sec-
tion [11], Option [2] must be set to OFF and Option [3] must be set to ON for this
option to be enabled.    Default - OFF
Option 4 - No Service Available
All Modes
This trouble is indicated If the system is unable to detect cellular service.
Default - ON
Option 5 - Radio Failure
All Modes
This trouble is indicated if there is an internal fault with the cellular radio.
Default - ON
Option 6 - PC5108 Failure
Mode 3
This trouble is indicated if a PC5108 supervisory or Keybus fault occurs. 
NOTE:  The PC5108 tamper is communicated only, therefore it can only be
enabled by turning on section 20 option 7 and section 21 option 5.  There is no
local annunciation for this event.    Default - ON
Option 7 -  Failure to Communicate (FTC)
All Modes
This trouble will be indicated if no acknowledgement has been received from
Connect 24 after three attempts.    Default - ON
Option 8 - Skyroute CL3050 Tamper
All Modes
This trouble will be indicated if the cover is removed from the Skyroute CL3050
activating the on-board tamper switch.    Default - OFF
[15] System Time
All Modes
When the time and day have been programmed, the values are saved and are
used as the current time and day whenever the Skyroute CL3050 does a power
up. Time and day programming is only required if the installer desires the Sky-
route CL3050 to test transmit at a specific time and/or day.  There is no "loss of
time" trouble on the Skyroute CL3050.
Default - 0000 - 2359
Zx
COM
Control Panel
RED    BLK YEL  GRN  COM  PGM
5.6K
Skyroute CL3050