Digital Security Controls Ltd. 05SKYCL User Manual

Page of 28
Skyroute CL3050  Universal Wireless Communicator
13
NOTE: If AC Power is detected, it will be used to provide the time base for the
internal clock. If AC power is not detected the internal clock will automatically
use the crystal time base.
[16] System Day of the Week
All Modes
See section [15]. 
Option 1. (Sunday) Default - ON
Option 2 - 8. (Monday - Saturday) Default - OFF
[17] Test Transmission Time
All Modes
When the Skyroute CL3050 is powered up for the first time, or after a default 
reset; it will check if the test transmission time and day are programmed.  If they 
are not, a random time (0000 - 2359) will be programmed into this location.  The 
Skyroute CL3050 will randomly generate this value.
NOTE:  Due to traffic volume, when selecting test transmission times, select a
time that is not on the :30 minute mark (e.g., 02:24, 04:07).
[18] Test Transmission Day
All Modes
When the Skyroute CL3050 is powered up for the first time, or after a default, it
will check if the test transmission time and day are programmed.  If they are not,
a random day (Sunday-Saturday) will be programmed into this location. The Sky-
route CL3050 will randomly generate this value. Because one test transmission
weekly is the most common configuration, this will allow the installer to setup
the Skyroute CL3050 without keypad programming.
Option 1-8. Default - [Random] - One only will be enabled.
[20] Transmission Options
All Modes
When the following options are enabled the reporting codes listed in Appendix A 
are sent to Connect 24.
Options 1, 2 - Zone Alarm/Zone Alarm Restores
Modes 2, 3
When a zone is violated or restored, the reporting codes listed in Appendix A will
be sent.
NOTES:  If generic reporting is enabled and multiple alarms occur during the
delay programmed in Section [23], only one alarm reporting code will be sent.
Zone alarm restorals enabled with generic zone reporting enabled can cause
unpaired events to be sent to Connect 24.
Option 1. Default - ON, Option 2. Default - OFF
Options 3, 4 - Zone Fault, Zone Fault Restores
Modes 2, 3
When the system sees a short circuit across any zone, a zone fault is generated.
DEOL resistors are required for zone fault reporting. In Section [11], Option [2]
must be set to OFF and Option [3] must be set to ON; In Section [13], Option 3
must be set to ON and the Skyroute CL3050 must be operating in mode 2 or 3.
Option 3. Default - OFFOption 4. Default - OFF
Options 5, 6 - Zone Tamper, Zone Tamper Restores
Modes 2, 3