Digital Security Controls Ltd. 06PC5132 User Manual

Page of 24
7
4.1 Program Zones and Partitions
Now that you have enrolled the wireless devices, you should complete all zone
programming on the system. Although the exact programming required varies
depending on which control panel the RF5132-433 is connected to, you should
check that the following programming areas are completed correctly for each
wireless zone:
• Enable zones and/or assign zones to one or more partitions (programming
sections [202]-[205] or [202] to [265] for the PC5020/PC1616/PC1864).
• Program the definition for each zone (programming sections [001]-[004]).
• Enable the wireless zone attribute for each wireless zone (PC580, PC1555,
PC1616, PC1864, PC501X v2.0, PC5020 v3.0 and higher only) (sections
[101]-[132]).
See your system Installation Manual, for more information on each of the above
programming sections.
4.2 Enable RF5132-433 Supervision
The control panel will supervise the RF5132-433 receiver via the Keybus after at least
one device has been enrolled on the module (see section 3.2 “Enrolling Wireless
Devices”).
To activate module supervision, after you enroll the first device(s):
1. Exit and then re-enter installer’s programming
2. Enter programming section [902]. Wait approximately 1 minute.
3. To exit press [#].
The system will generate a General System Supervisory trouble if the module is
removed from the Keybus. If you need to remove the RF5132-433 module from an
existing system, you will have to disable supervision of the RF5132-433.
NOTE:  Deleting all devices from the RF5132-433 or defaulting the RF5132-433 will
cause a supervisory fault
To disable RF5132-433 supervision:
1. Disconnect the RF5132-433 from the Keybus
2. Enter [*][8][Installer Code]
3. Enter [902]. The control panel will clear all supervision and re-scan the system for
connected modules. The scan will take approximately one minute.
4. To exit press [#].
To review which modules the control panel is currently supervising:
1. Enter [*][8][Installer’s Code]
2. Enter [903] to display all modules. On LED keypads, light [17] will indicate
that the RF5132-433 is present on the system. On LCD keypads, scroll until
the module name appears on the display.
3. To exit press [#].
S E C T I O N  4