Digital Security Controls Ltd. 163G4005 User Manual

Page of 49
36
Universal Cellular Communicator
Periodic SMS/Call First Send: Select the date /hour on which the first periodic SMS/voice message is to be sent.
To comply with the EN50136-2:2013 standards the time “Periodic SMS/Call First Send” should be set equal to 1 day and this
function should not be changed (default: 1 day).
You MUST enter the “SIM Phone Number” and enable the “Auto SMS” and “IP Clock Adjust “in the “Options” page to setup
the Periodic options above.
Now: if click on this icon you can get the date and time from the PC. 
Ring only for periodic event: if this option is enabled, instead of sending a voice message a periodic ring will be sent for
5 sec.
Phone Number Use: 1 SMS Phone Numbers; 2 Voice Dialer Phone Numbers.
Double Click on 1 to enable phone numbers for SMS Communicator, 8 of 32 phone numbers of the phonebook;
Double Click on 2 to enable phone numbers for Voice Communicator, 8 of 32 phone numbers of the phonebook;
This section is used to program all parameters relating to the SMS/voice dialer, namely: the telephone numbers to call (the first 8
numbers in the phonebook):
Label: this column lists the events for which a voice message may be programmed.
To select voice messages for the programmable input lines, set the corresponding terminal as an input (see I/O-Type).
Telephone Numbers: click on [+] Telephone Numbers columns in accordance with the desired event. The tick indicates that a
particular telephone number will be called when an event occurs. Click on the boxes to enter/remove the tick.
The telephone numbers are the first 8 entries on the “Phonebook” page.
Voice Messages: click on the column First Message in accordance with the desired event, then click on the button [ ...] to
scroll through the list of messages (you can select, if recorded, up to 8 messages with a max. duration of 16 seconds each)
and select one. Up to 3 voice messages can be selected for each event (First Message, Second Message, Third Message).
For setting SMS Dialer...
Label: this column has 31 separate lines listing the events for which two SMS messages are sent, if programmed: one for acti-
vation and one for restore (the "Periodic SMS" event only sends an activation SMS).
To select SMS messages for the programmable input lines, set the corresponding terminal as an input (see I/O->Type).
SMS Telephone Numbers: click on [+] SMS Telephone Numbers in accordance with the desired input. A tick indicates that the
SMS message will be sent to a particular telephone number when the corresponding event occurs.
The telephone numbers are the first 8 entries on the “Phonebook” page.
SMS Test: in the column SMS Test, click the box corresponding to the message to be programmed and enter the message
you wish to send when the relevant event occurs (maximum 100 characters).
Central Station Calls
The following options to program the communicator to send an alarm event to the central station.
PERIODIC CALL
Periodic Test Transmission Intervalenter the interval in which the Periodic Test will be carried out. The interval consists of
the following values:
— (Days) next Test day - Select the day value for the next Periodic Test. The interval for these values may be set between 1
and 364.
— (Hours) next Test time - Select the hour value for the next Periodic Test. The interval for these values may  be set
between 1 and 23.
Test Transmission First test: Select the date /hour in which the First Periodic Test  will be carried out.
Now: if click on this icon you can get the date and time from the PC.