Digital Security Controls Ltd. 163G4005 User Manual

Page of 49
6
Universal Cellular Communicator
Technical Specifications
The supply voltage for this communicator is provided by the Control panel connected (10.7 V to 27.6 V) or from an external power
supply that provides the 12 V and recharging, if necessary, a back-up battery (accessory item). The only purpose of the battery is
to provide the power in the event the primary power source is lost. The required autonomy in stand-by is 8 hours.
In both cases, if the main power is lost the battery assures that the panel will still powered and working. 
The main power voltage and the battery voltage will be supervised.
The power supply for the Communicator models GS4005, 3G4005/AM and 3G4005/EU shall be:
SELV type;
Limited power;
Limited to 1 A.
Model
GS4005-K
3G4005-K/AM
3G4005-K/EU
GS4005
3G4005/AM
3G4005/EU
Input Voltage
10.7 to 27.6 V
_
Standby average cur-
rent, without battery
90 mA (not including outputs) @ 13,8 V
_
Maximum current drawn 
in current limited mode
230 mA (not including outputs) @ 13,8 V
_
Maximum current drawn
450 mA (not including outputs) @ 13,8 V
_
Outputs
6 open-collector, 100 mA
Operating frequency 
(MHz)
900/1800
850/1900
GSM: 850/1900
UMTS: 850/1900
GSM: 900/1800
UMTS: 900/2100
900/1800
850/1900
GSM: 850/1900
UMTS: 850/1900
GSM: 900/1800
UMTS: 900/2100
Maximum loop resistance 
of line between the device 
connected in series on LI
1 Kohm
Maximum number of paral-
lel devices connected on LI
1
Environmental class
II
Operating Temperature
-10 to +40 °C
Humidity
0 to 95%
Dimensions (WxHxD)
76x151x20 mm (PCB only)
101x186x41 mm
Weight
66 g
250 g
Table 1: Technical specifications.
Interface type between SPT (Supervised Premises Transceiver) 
and AS (Alarm System) 
Proprietary interface
ATS (Alarm Transmission System)
SINGLE PATH
Alarm Transmission System performances
SP4 for digital messages SP2 for vocal/text messages
Average transmission time
D3 (20 s)
D2 (60 s)
Maximum transmission time
M3 (60 s)
M2 (120 s)
Reporting time
T4 (180 s)
T2 (25 h)
Substitution security
S2
S0
Information security
I3
I0
Table 2: EN 50136-1:2012 e EN 50136-2:2013 specifications.