Digital Security Controls Ltd. 18LE2077 User Manual

Page of 51
9
C24 C
OMMUNICATIONS
1
 A
CCOUNT
 
AND
 SIM 
CARD
 A
CTIVATION
(Before Installation)
Installation of the Communicator requires activation with Connect24 before operation. Dealer 
application forms and additional information on the Connect24 Voice Response Unit (VRU) and 
graphical user interface (GUI) can be found at http://www.Connect24.com or by telephone at: 
USA 1-888-251-7458 or CANADA 1-888-955-5583.
IMPORTANT: Prior to installing a LE2077 or TL2553G Communicator, contact your monitor-
ing station to determine if it is a master re-seller or visit http://www.Connect24.com to become 
an authorized dealer. In either instance, you will require a Profile Number, Installer ID Number, 
and an Installer Password. Perform the following pre installation:
1. Retrieve the installer account and password from the master reseller, or from Connect24
directly.
2. Connect your browser to the Connect 24 website at: http://www.Connect24.com or use
the mobile website m.connect24.com.
3. Log in to the Connect24 website using your installer account and password.
4. Perform the following steps in a Connect24 session to activate the SIM card and initialize
programming:
a. Navigate to the Initialize an account section.
b. Select Profile (This information will be provided by the master reseller or by Connect24).
c. Select Product Module.
d. Enter the SIM card number.
e. Click Next then enter in all relevant information as required.
f. Confirm all information is entered correctly before submitting.
5. Repeat Step 4 to program another SIM card (i.e. another Subscriber), or log out from
Connect24.
6. When you are at the physical installation site, the Communicator will automatically connect
and download its programming from Connect24 once the unit is initialized.
NOTE: Following initial installation, you can log in to the Connect24 website at any time to re-
configure the Communicator remotely, using the account created for this installation. For more 
information, refer to the Connect24 website.
Before leaving the installation site, the Communicator TL2553G shall be connected via an 
APPROVED (acceptable to the local authorities) Network Interface Device (NID) (e.g., for UL 
Installations, U60950 listed NID). All wiring shall be performed according to the local electrical 
codes.
E
NCRYPTION
The Communicator uses 128 Bit AES Encryption. Encryption can only be enabled from the 
monitoring station receiver. Each receiver can independently have encryption enabled or dis-
abled. When encryption is enabled, the central station will configure the device to encrypt com-
munications the next time the Communicator module performs a communication to that 
receiver. 
NOTE: Packets will start being encrypted only after the next event is sent to that receiver, or if 
the unit is restarted.
C
OMMUNICATOR
 P
RE
 I
NSTALLATION
 C
ONFIGURATION
1. Connect24, DSC, and DLS IV are Registered Trademarks of Tyco International Ltd. and its respective Companies. All
Rights Reserved.