Digital Security Controls Ltd. 18PG9303 User Manual

Page of 8
D-307447 PGx303
Installation Instructions
©2018 Tyco Security Products
www.dsc.com
Tech. Support: 1-800-387-3630
PGx303 installation instructions
Supervised vanishing magnet ic cont act
Overview
The PGx303 is a thin, ultra long- life PowerG magnetic
contact device that is compatible with DSC wireless
receivers. The wireless device includes a built-in reed
switch that opens a circuit when the magnet is moved
from its normal position.
NOTE: The in the product name PGx303 can be
replaced by one of the following numbers: 4,8,9. 4
refers to the frequency 433 MHz, 8 refers to 868
MHz and 9 refers to 912 MHz - 919 MHz.
Figure 1:
PGx303
1: Device
2: Magnet
l
Two-way PowerG communication with the control
panel
l
Front and back cover tamper detection
l
LED light signal strength indication during install-
ation
l
Discreet transmission of supervision message
l
PowerG two-way frequency hopping spread spec-
trum time-division multiple access (FHSS-TDMA)
technology
l
Low battery indication
Installation
CAUTION! Service personnel only may install this
equipment. Place this device in non-hazardous indoor
locations only.
NOTES:
Install the PGx303 in accordance with the Standard
for Installation and Classification of Residential Burg-
lar Alarm Systems, UL 1641.
To comply with FCC and IC RF exposure compliance
requirements, locate the device at a distance of at
least 20 cm from all persons during normal operation.
Do not co- locate the antennas used for this product, or
operate them in conjunction with any other antenna or
transmitter.
M ount ing t he device ( quick inst allat ion)
NOTE: 
Do not use this method for UL installations as
UL certified devices must be mechanically secured.
1.
Peel the release liners off the two strips of double-
sided adhesive tape and attach the tape to the back
of the device and the magnet. See Figure 2.
2.
Place the device on the frame of a window or
door and place the magnet on the moving surface
of the door or window itself, directed according to
the location marks. See Figure 3.
NOTE: See Typical reed switch positions for more
information on alignment.
Figure 2: Quick installation
1: Double- sided adhesive tape
2: Enrollment / battery tab
Figure 3: Device and magnet position on door and
door frame
M ount ing t he device ( screw inst allat ion)
To mount the device with screws, complete the fol-
lowing steps:
1.
Insert a coin in the slot and twist to remove the
cover. See Figure 4.1. If a coin is not available,
insert a 4 mm flat screwdriver into each slot of the
plastic cover and twist to open each side. See Fig-
ure 4.2.
2.
Screw the device base onto the door frame. See
Figure 5.
3.
Screw the magnet base on to the door, aligning it
with the line on the device. See Figure 3.
NOTE: See Typical reed switch positions for
more information on alignment
4.
Clip the covers on to the device and magnet base
(see Figure 7).
Figure 4: Device cover removal
Figure 5: Device screw installation
Figure 6: Magnet screw installation
Figure 7: Closing the device cover
Enrolling t he device
To enroll the device, complete the following steps:
NOTES:
Refer to the panel installer guide and follow the pro-
cedure under the 02:ZONES/DEVICES option of the
installer menu.
For UL/ULC listed installations use only in conjunction
with UL/ULC listed control panels.
Figure 8: Battery/enrollment tab
Refer to the panel installation manual for the enroll-
ment procedure. A general description of the pro-
cedure is provided below:
1.
To ensure that the proper steps are used, refer to
the installation manual for the alarm system that
the device is being enrolled on.
2.
Enter the device enrollment option through the spe-
cified method and select the appropriate option to
add the new device.
3.
Enroll the device by either inserting the battery to
power on the device until the enrollment is detec-
ted, or by entering the device ID.
4.
Select the desired zone number.
5.
Configure any device parameters that are
required.
6.
Mount and test the detector. See walk testing for
information on testing the device. In addition, see
the alarm systems installation manual that the
device is enrolled on for other test procedures that
are required.
If the detector is already enrolled, you can configure
the detector parameters by programming the system,
see the alarm systems installation manual for more
information about device parameters.
NOTE: When enrolling the detector to WP panels
with version 19.4 or lower, the detector is enrolled as
ID:100-XXXX , and labeled Contact in the panel.
Replacing t he bat t ery
CAUTION! 
Risk of explosion if battery is replaced by
an incorrect type. Dispose of used batteries according
to the manufacturer's instructions.
WARNING! This product contains a coin battery. If it
is swallowed, it can cause severe internal burns in just
2 hours and can lead to death. Keep new and used bat-
teries away from children. If the battery compartment
does not close securely, stop using the product and
keep it away from children. If you think batteries
might have been swallowed or placed inside any part
of the body, seek immediate medical attention.
To remove the battery, complete the following steps:
1.
Remove the cover. See Figure 4.
2.
Wedge a flat head screwdriver under the battery.
See Figure 9.1.
3.
Twist the screwdriver using the base as a lever to
remove the battery.
Figure 9: Battery removal and insertion
To insert the battery, complete the following steps:
1.
Insert the battery at an angle while observing bat-
tery polarity. See Figure 9.2.
2.
Press down on the battery until it fits into place.
Typical reed switch positions
The following table displays the range coverage dir-
ections of the PGx303.
Table 1: Typical reed switch positions
Wood
Supports Iron
Opening
Closing
Direction Opening
Closing
>22 mm
(0.87 in.)
< 19 mm
(0.75 in.)
X
> 9 mm
(0.35 in.)
< 5 mm
(0.20 in.)
> 16 mm
(0.63 in.)
< 14 mm
(0.55 in.)
Y
> 12 mm
(0.47 in.)
< 10 mm
(0.40 in.)
> 27 mm
(1.06 in.)
< 25 mm
(0.98 in.)
Z
> 18 mm
(0.71 in.)
< 15 mm
(0.60 in.)
Figure 10: Range coverage directions
Local diagnostics test
Before testing, separate the cover from the base ( see
Figure 4), then complete the following steps:
1.
Close the cover to return the tamper switch to its
normal (undisturbed) position.
2.
Momentarily open the door or window and verify
the red LED blinks, indicating detection.
3.
After two seconds, one of the LEDs blinks three
times.
Table 2 displays received signal strength indication:
Table 2: Signal strength indication
LED response
Reception
Green LED blinks
Strong
Yellow LED blinks
Good
Red LED blinks
Poor
No blinks
No communication
IMPORTANT! Reliable reception must be assured.
Therefore, poor signal strength is not acceptable. If
you receive a poor signal from the detector, re-locate
it and re- test until a strong signal strength is received
(in regions requiring UL-compliant installation, only
strong signal strength is permitted).
NOTE: It is recommended to have a strong signal
strength and you must verify the signal strength using
the control panel's diagnostic test. For detailed Dia-
gnostics Test instructions, refer to the control panel
installer guide.
Specifications
WIRELESS
Frequency: 433, 868, 915 (in accordance with the pre-
vailing frequency of your region).
Note: Only devices in frequency band 912 MHz - 919
MHz are UL/ULC listed
Maximum Tx Power: +14 dBm radiated @ 868 MHz;
+10 dBm radiated @ 433 MHz
Modulation: GFSK
Antenna: Built- in inverted-F antenna
Communication protocol: PowerG
Supervision: Signaling at 256 second intervals
ELECTRICAL
Battery Type: 3 V Lithium CR2450 Panasonic battery
only
Battery Life: 6 years with typical use at room tem-
perature 25°C (77°F)
NOTE: Not verified by UL
Low Battery Threshold: 2 V at room temperature 25°C
(77°F)
ENVIRONMENTAL
Operating temperature: -10°C (14°F ) to 55°C (131°F).
UL verified range: 0ºC (32°F) to 49ºC (120°F ) only
Storage Temperature: -20°C to 70°C (-4°F to 158°F)
Relative Humidity (RH): Up to 95% non-condensing,
UL verified up to a maximum of 85% RH only
PHYSICAL
Size (LxWxD): 67 mm x 31 mm x 11 mm (2.6 in. x 1.2
in. x 0.4 in.)
Weight (with battery): 20 g (0.71 oz)
Color: White or Brown
UL/ULC Not es
Only model PG9303 operating in the frequency band
912-919MHz is UL/cUL listed. The PG9303 has been
listed by UL/cUL for commercial and residential burg-
lary applications in accordance with the requirements
in the Standards UL 634 and ULC/ORD-C634 for con-
tacts and switches. For UL/ULC installations use these
device only in conjunction with compatible DSC wire-
less receivers: HSM2HOST9, HS2LCDRF(P)9,